Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: MAGNA ENERGY SERVICES, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MAGNA ENERGY SERVICES, LLC in 23295 US HWY 85, LA SALLE, CO 80645 (NAICS 213112). OSHA activity number 330987850.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Magna Energy Services, LLC for free Get an email when a new federal OSHA severe-injury report for Magna Energy Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
23295 US HWY 85
City
LA SALLE
State
CO
ZIP
80645
Mailing
23295 US HWY 85, LA SALLE, CO 80645
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
95
Ownership type
Private (A)

18 citations on file for this inspection.

1910.146 C01

Serious Gravity 5 6 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:    (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/14/11, the employer did not evaluate the workplace for the presence of permit-required confined spaces. Employees entered tanks, which were used to store processed water in the oil fields, to perform cleaning operations. This condition exposed employees to hazardous atmospheric conditions.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $5000

1910.146 C02

Serious Gravity 5 5 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces:                   	  (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/14/11, the employer did not ensure that permit required confined spaces were marked with appropriate warning signs.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.146 C04

Serious Gravity 5 5 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.146(c)(4): The employer did not implement a written permit space program that complied with this section. A written program was not available for inspection by employees:     (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/14/11, the employer did not implement a written permit space program. Employees entered tanks, which were used to store processed water in the oil fields, to perform cleaning operations. The employer considered the space as a permit-required confined space. This condition exposed employees to hazardous atmospheric conditions.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $5000

1910.146 D02

Serious Gravity 5 5 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.146(d)(2): The employer did not identify and evaluate the hazards of permit spaces before employees were required to enter the space:     (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/14/11, the employer did not evaluate hazards of the permit space prior to entering the space. Employees entered tanks, which were used to store processed water in the oil fields, to perform cleaning operations. This condition exposed employees to hazardous atmospheric conditions.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.146 D05 I

Serious Gravity 5 5 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.146(d)(5)(i): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not evaluate permit space conditions when entry operations were conducted by testing conditions in the permit space to determine if acceptable entry conditions existed before entry was authorized to begin:    (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/14/11, the employer did not evaluate hazards of the permit space prior to entering the space. Employees entered tanks, which were used to store processed water in the oil fields, to perform cleaning operations. This condition exposed employees to hazardous atmospheric conditions.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.146 E01

Serious Gravity 5 5 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.146(e)(1): Before entry is authorized, the employer did not document the completion of measures required by paragraph (d)(3) of the section by preparing an entry permit:     (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/14/11, the employer did not ensure that permit required confined space entry permits were completed prior to entering the space. Employees entered tanks, which were used to store processed water in the oil fields, to perform cleaning operations. This condition exposed employees to hazardous atmospheric conditions.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.146 K01 I

Serious Gravity 5 5 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.146(k)(1)(i): The employer did not ensure that each member of the rescue service was provided with, and trained to use properly the personal protective equipment and rescue equipment necessary for making rescues from permit spaces:                                                               (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/14/11, the employer did not evaluate emergency rescue service capabilities prior to employee access to permit required confined spaces. Employees entered tanks, which were used to store processed water in the oil fields, to perform cleaning operations.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.146 G01

Serious Gravity 5 5 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work is regulated by this section acquire the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under this section:     (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/14/11, the employer did not ensure that employees were provided training to ensure that they had the understanding, knowledge, and skill necessary for safe performance while working inside a permit-required confined space.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.215 A04

Serious Gravity 1 3 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $2,550 · Current $1,530 Reduced
29 CFR 1910.215(a)(4): The employer did not ensure that work rests were present and kept adjusted closely to the grinding wheel with a maximum opening of one-eighth of an inch:    (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/14/11, the employer did ensure that work rests were present on the 8-inch Central Machinery Industrial 8inch Bench Grinder/Buffer. This condition exposed employees to including, but not limited to, laceration hazards.
Recent events (2)
  • · I (S) $1530
  • · Z (S) $2550

1910.215 B09

Serious Gravity 1 3 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The employer did not ensure that the grinding wheel was equipped with an adjustable tongue guard:     (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/14/11, the employer did ensure that tongue guards were present on the 8-inch Central Machinery Industrial 8inch Bench Grinder/Buffer. This condition exposed employees to including, but not limited to, laceration hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.22 D01

Other-than-serious 6 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed to the building:    (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/14/11, the employer did not ensure that the parts room located above the equipment store room was equipped with a load rating.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.134 E01

Other-than-serious 2 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator before the employee was required to use the respirator in the workplace:     (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/13/11, the employer did not ensure that medical evaluations were provided to employees prior to their use of a respirator. Employees donned an MSA half-face, tight-fitting, air-purifying respirator, equipped with combination filters when entering tanks that were used to store processed water in the oil fields. Employees entered tanks to conduct cleaning work. This condition exposed employees to respiratory hazards.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.134 F02

Other-than-serious 2 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2):  Employees using tight-fitting facepiece respirators were not fit tested whenever a different respirator facepiece (size, style, model or make) was used:    (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/13/11, the employer did not ensure that fit tests were provided to employees prior to their use of a respirator. Employees donned an MSA half-face, tight-fitting, air-purifying respirator, equipped with combination filters when entering tanks that were used to store processed water in the oil fields. Employees entered tanks to conduct cleaning work. This condition exposed employees to respiratory hazards.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.134 K01

Other-than-serious 2 exposed
Issued
Dec 2, 2011
Abate by
Dec 17, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(1): The employer did not provide training prior to requiring employees to use respirators in the workplace:     (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/13/11, the employer did not ensure that respirator training was provided to employees prior to their use of a respirator. Employees donned an MSA half-face, tight-fitting, air-purifying respirator, equipped with combination filters when entering tanks that were used to store processed water in the oil fields. Employees entered tanks to conduct cleaning work. This condition exposed employees to respiratory hazards.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.178 A06

Other-than-serious 3 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(6): Nameplates or markings for powered industrial trucks were not maintained in a legible condition:    (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/14/11, the employer did not ensure that the Nissan SD-33 diesel forklift was equipped with a nameplate or marking.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.178 Q06

Other-than-serious 3 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.176(q)(6): The employer did not ensure that industrial trucks were not altered so that the relative positions of the various parts were different from what they were when originally received from the manufacturer, to include the elimination of any parts:     (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/14/11, the employer did not ensure that the Nissan SD-33 diesel forklift was equipped with a seat belt as provided from the manufacturer.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.212 A01

Other-than-serious 3 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/14/11, the employer did ensure that the rotating chuck on the Central Machinery Industrial Drill Press was guarded from incidental contact while in operation. This condition exposed employees to, including but not limited to cuts and abrasions.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 F05 II

Other-than-serious 3 exposed
Issued
Dec 2, 2011
Abate by
Jan 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:      (a) Magna Energy Services, Inc., @ 23295 US Hwy 85, LaSalle, CO 80645: On and before 9/14/11, the employer did not ensure that containers storing oil were maintained labeled containers. Containers were color coded with a green or blue lid which did not include a hazard warning.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Magna Energy Services, LLC's full OSHA safety record →