Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. GEOLOGICAL SURVEY - CARSON CITY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. GEOLOGICAL SURVEY - CARSON CITY in 2730 N. DEER RUN ROAD, CARSON CITY, NV 89701 (NAICS 924120). OSHA activity number 331065003.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Geological Survey - Carson City — free Get an email when a new federal OSHA severe-injury report for U.S. Geological Survey - Carson City is published. One employer, no account, unsubscribe in one click.
Site address
2730 N. DEER RUN ROAD
City
CARSON CITY
State
NV
ZIP
89701
Mailing
2730 N. DEER RUN ROAD, CARSON CITY, NV 89701
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
62
Ownership type
D

10 citations on file for this inspection.

1910.178 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 21, 2011
Abate by
Sep 30, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(2): All new powered industrial trucks acquired and used by the employer did not meet the design and construction requirements for powered industrial trucks established in the American National Standard for Powered Industrial Trucks, Part II, ANSI B56.1-1969, which was incorporated by reference as specified in 29 CFR 1910.6:    (a) At the USGS warehouse, the emergency brake on the Yale forklift had a broken handle and vice grips were used in lieu of a brake release handle.
Recent events (1)
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 21, 2011
Abate by
Sep 26, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not seperated from fuel-gas cylinders or combustible materials (especially oil and grease) a minium distance of 20 feet (6.1 m) or a noncombustible partition having a fire-resistant rating of of at least one hour:    (a) In the USGS warehouse, oyxgen and acetylene gas cylinders were stored together on the welding cart and adjacent to other petroleum products.
Recent events (1)
  • — Z (S) $0

1910.253 B02 IV

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 21, 2011
Abate by
Sep 26, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place and hand-tight, except when cylinders were in use or connected for use:  (a) In the warehouse, on the welding cart, stored oxygen and acetylene fuel gas cylinders valves were not covered with a cap.
Recent events (1)
  • — Z (S) $0

1910.303 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 21, 2011
Abate by
Sep 26, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:    (a)  In the USGS warehouse, on the workbench, an orange extension cord, used to supply power to electrical equipment, had torn insulation and bare copper wires were showing.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 21, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) In room 207 of the USGS, two relocatable power taps were daisy chained together.
Recent events (1)
  • — Z (S) $0

1910.303 G01

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 21, 2011
Abate by
Sep 26, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment:    (a) In the USGS warehouse area, air circulation for the air cooled transformer was blocked by boxes of supplies and other materials.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 21, 2011
Abate by
Sep 26, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    (a) In the room 207, a relocatable power tap, used to plug in a desk top computer, was permanently attached to the table with screws.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 21, 2011
Abate by
Sep 26, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    (a) In the USGS Laboratory room, the power cord of the Blue M Oven did not have strain relief and the outer sheath was pulled away from the insulation.
Recent events (1)
  • — Z (S) $0

1910.22 D01

Other-than-serious 1 instance 4 exposed
Issued
Sep 21, 2011
Abate by
Oct 12, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked in a conspicuous place in each space to which they related:    (a)  In the USGS Warehouse, the Mezzanine Deck Storage area did not have its load capacity posted.
Recent events (1)
  • — Z (O) $0

1910.157 C01

Other-than-serious 1 instance 1 exposed
Issued
Sep 21, 2011
Abate by
Sep 26, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    (a) In room 147, electronic shop, the portable fire extinguisher was mounted on the wall without a sign to identify its location.
Recent events (1)
  • — Z (O) $0

View U.S. Geological Survey - Carson City's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331065003.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.