OSHA Inspection: EUREKA CONSTRUCTION CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EUREKA CONSTRUCTION CORPORATION in SUNFLOWER PLAZA RETAINING WALL PROJECT TUMON, TAMUNING, GU 96913 (NAICS 238110). OSHA activity number 331083238.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Eureka Construction Corporation — free Get an email when a new federal OSHA severe-injury report for Eureka Construction Corporation is published. One employer, no account, unsubscribe in one click.
Site address
SUNFLOWER PLAZA RETAINING WALL PROJECT TUMON
City
TAMUNING
State
GU
ZIP
96913
Mailing
114 CHATO COURT, SINAJANA, GU 96910
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
15
Ownership type
A

5 citations on file for this inspection.

1926.452 A03

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 27, 2011
Abate by
Dec 30, 2011
Penalty
Initial $2,040 · Current $0 Reduced
29 CFR 1926.452(a)(3): Diagonal bracing in both directions was not installed across the entire inside face of double-pole scaffolds used to support loads equivalent to a uniformly distributed load of 50 pounds (222 kg) or more per square foot (929 square cm):    (a) At the project on or about October 31, 2011, and at times prior thereto, there was no diagonal bracing in both directions on the inside face of the double-pole scaffold.  Employees were on the top scaffold platform to apply a finish coat to the retaining wall and were exposed to a fall from a height of about 18.66 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2040

1926.452 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 27, 2011
Abate by
Dec 30, 2011
Penalty
Initial $2,040 · Current $0 Reduced
29 CFR 1926.452(a)(4): Diagonal bracing in both directions was not installed across the entire outside face of all double- and single-pole scaffolds:    (a) At the project on or about October 31, 2011, and at times prior thereto, there was no diagonal bracing in both directions on the outside face of the double-pole scaffold.  Employees were on the top scaffold platform to apply a finish coat to the retaining wall and were exposed to a fall from a height of about 18.66 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2040

1926.452 A07

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 27, 2011
Abate by
Dec 30, 2011
Penalty
Initial $2,040 · Current $0 Reduced
29 CFR 1926.452(a)(7): Runners were not supported by bearing blocks securely attached to the poles:    (a) At the project on or about October 31, 2011, and at times prior thereto, the runners were not supported by bearing blocks attached to the poles.  Employees were on the top scaffold platform to apply a finish coat to the retaining wall and were exposed to a fall from a height of about 18.66 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2040

1926.452 A08

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 27, 2011
Abate by
Dec 30, 2011
Penalty
Initial $2,040 · Current $0 Reduced
29 CFR 1926.452(a)(8): Braces, bearers, and runners shall not be spliced between poles:    (a) At the project on or about October 31, 2011, and at times prior thereto, the runners were spliced between the poles.  Employees were on the top scaffold platform to apply a finish coat to the retaining wall and were exposed to a fall from a height of about 18.66 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2040

1926.95 A

Other-than-serious 1 instance 2 exposed
Issued
Dec 27, 2011
Abate by
Dec 30, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact:    (a) At the project on or about October 31, 2011, and at times prior thereto, eye protection was not worn while Portland cement was applied as a finish coat to a vertical retaining wall.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Eureka Construction Corporation's full OSHA safety record →