MILWAUKEE, WI —
OSHA Inspection: ARGON INDUSTRIES, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ARGON INDUSTRIES, INC. in 7026 N. TEUTONIA AVE., MILWAUKEE, WI 53209 (NAICS 332322). OSHA activity number 331088302.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARGON INDUSTRIES, INC.
- Site address
- 7026 N. TEUTONIA AVE.
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53209
- Mailing
- 8939 N. 55TH ST., MILWAUKEE, WI 53223
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 20
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.134 C01
- Issued
- Mar 13, 2012
- Abate by
- Mar 20, 2012
- Penalty
- Initial $4,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) Employees were required to wear the powered air purifying respirator when welding and there was no written respirator program.
Recent events (2)
- — I (O) $0
- — Z (S) $4200
1910.134 E01
- Issued
- Mar 13, 2012
- Abate by
- Mar 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Employees were required to wear the powered air purifying respirator when welding and did not have a medical evaluation.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.212 A01
- Issued
- Mar 13, 2012
- Abate by
- Apr 30, 2012
- Penalty
- Initial $4,200 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) The Fanuc I robotic welding machine had one opening with a fixed guardrail that was 21 1/2 inches high that allowed access and a second opening with a chain across the opening that was not interlocked with the robot movement that allowed access. (b) In the southwest corner of the shop the Hyd-Mech metal-cutting band saw did not have the un-used portion of the blade guarded.
Recent events (2)
- — I (S) $2100
- — Z (S) $4200
1910.22 D01
- Issued
- Mar 13, 2012
- Abate by
- Mar 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. (a) The storage area above the shipping office had no load limit sign posted.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 II
- Issued
- Mar 13, 2012
- Abate by
- Mar 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) At the Fanuc I work station the portable control box had an open knock out. (b) At the Fanuc I work station the junction box mounted on the wall had an open knock out.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B02 I
- Issued
- Mar 13, 2012
- Abate by
- Mar 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: (a) At the Fanuc I work station the junction box mounted on the wall had the cover hanging open.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Argon Industries, INC.
View Argon Industries, INC.'s full OSHA safety record →