Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PINNACLE PRECISION TECHNOLOGIES, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PINNACLE PRECISION TECHNOLOGIES, LLC in 2607 EATON LANE, RACINE, WI 53404 (NAICS 332116). OSHA activity number 331090233.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pinnacle Precision Technologies, LLC — free Get an email when a new federal OSHA severe-injury report for Pinnacle Precision Technologies, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2607 EATON LANE
City
RACINE
State
WI
ZIP
53404
Mailing
2607 EATON LANE, RACINE, WI 53404
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
14
Ownership type
A

4 citations on file for this inspection.

1910.147 C01

Willful 1 exposed
Issued
Mar 15, 2012
Abate by
May 4, 2012
Penalty
Initial $4,200 · Current $0 Reduced
29 CFR 1910.147(c)(1):     The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:      (a)  Employees are exposed to crushing hazards while servicing and maintaining equipment and the employer did not develope a written energy control (Lockout/Tagout) program.
Recent events (2)
  • — I (W) $0
  • — Z (S) $4200

1910.147 C04 I

Serious Gravity 10 1 exposed
Issued
Mar 15, 2012
Abate by
May 4, 2012
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1910.147(c)(4)(i):     Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:     (a)  Employees are exposed to crushing hazards while servicing and maintaining equipment and the employer did not develope energy control procedures to address all energy sources.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $4200

1910.217 B07 X

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 15, 2012
Abate by
Apr 5, 2012
Penalty
Initial $4,200 · Current $4,200
29 CFR 1910.217(b)(7)(x):     Foot operated control(s) used on mechanical power press(es) with part revolution clutches were not protected to prevent operation from falling or moving objects, or from unintended operation by accidental stepping onto the foot control.      (a)  Employees were exposed to amputation hazards while the Biss 39 BM press, which was located in the machine shop, and the employer did not ensure that foot pedal was protected from unintentional operations.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $4200

1910.217 C01 I

Serious Gravity 10 5 instances 5 exposed
Issued
Mar 15, 2012
Abate by
Apr 20, 2012
Penalty
Initial $4,200 · Current $0 Reduced
29 CFR 1910.217(c)(1)(i):     The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es)    (a)  Employees were exposed to amputation hazards while operating the Federal (Model #110 O.B.I.) part revalution power press and the employer did not ensure that the point of operation was properly guarded.     (b)  Employees were exposed to amputation hazards while operating the Bliss (model Number 39 BM) part revaloution power press and the employer did not ensure that that the point of operation was properly guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4200

View Pinnacle Precision Technologies, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331090233.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.