RACINE, WI —
OSHA Inspection: PINNACLE PRECISION TECHNOLOGIES, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PINNACLE PRECISION TECHNOLOGIES, LLC in 2607 EATON LANE, RACINE, WI 53404 (NAICS 332116). OSHA activity number 332838325.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PINNACLE PRECISION TECHNOLOGIES, LLC
- Site address
- 2607 EATON LANE
- City
- RACINE
- State
- WI
- ZIP
- 53404
- Mailing
- 2607 EATON LANE, RACINE, WI 53404
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332116
- Employees
- 14
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.217 E01 I
- Issued
- Sep 21, 2012
- Abate by
- Nov 16, 2012
- Penalty
- Initial $4,200 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: (a) Employees were exposed to amputation hazards while operating mechanical power press and the employer did not establish a program of perfiodic and regular inspections of the mechanical power presses.
Recent events (2)
- — I (S) $3000
- — Z (S) $4200
1910.217 E01 II
- Issued
- Sep 21, 2012
- Abate by
- Nov 16, 2012
- Penalty
- Initial $4,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.217(e)(1)(ii): Mechanical power press(es) were not inspected and tested at least weekly to determine the condition of the clutch/brake mechanism,anti-repeat feature and single stroke mechanisms. (a) Employees were exposed to amputation hazards while operating mechaincal power presses and the employer did not inspect and test at least weekly to determine the condition of the clutch/brake mechanism and anti-repeat feature.
Recent events (2)
- — I (S) $0
- — Z (S) $4200
More inspections at Pinnacle Precision Technologies, LLC
View Pinnacle Precision Technologies, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332116)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332838325.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.