PUEBLO, CO —
OSHA Inspection: MIDWEST FABRICATION & STEEL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MIDWEST FABRICATION & STEEL, INC. in 1015 E. NORTHERN AVE., PUEBLO, CO 81006 (NAICS 332313). OSHA activity number 331102772.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MIDWEST FABRICATION & STEEL, INC.
- Site address
- 1015 E. NORTHERN AVE.
- City
- PUEBLO
- State
- CO
- ZIP
- 81006
- Mailing
- 1015 E. NORTHERN AVE., PUEBLO, CO 81006
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332313
- Employees
- 38
- Ownership type
- A
Citations
20 citations on file for this inspection.
1910.22 A01
- Issued
- Apr 11, 2012
- Abate by
- Apr 16, 2012
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. a) On or about December 7, 2011, employer did not ensure that employees were protected from tripping hazards while working and walking near the welding and cutting area and in the compressor area where there was metal materials, equipment, trash, and parts on top of each other in an disorderly manner.
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
1910.23 A08
- Issued
- Apr 11, 2012
- Abate by
- Apr 16, 2012
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded: a) On or about December 7, 2011, employer did not ensure that employees were protected from tripping hazards while working and walking near the DNC Machine where there was a floor opening next to the machine (12 inches by 24 inches).
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
1910.24 F
- Issued
- Apr 11, 2012
- Abate by
- May 23, 2012
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.24(f): Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs: a) On or about December 7, 2011, employer did not ensure that employees were protected from tripping injuries while walking up and down a set of fixed stairs in the warehouse area where the rungs of the stairs were damaged (bent) and not uniform.
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
1910.36 D01
- Issued
- Apr 11, 2012
- Abate by
- Jul 25, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: a) On or about December 7, 2011, employer did not ensure that employees were protected from injuries during an emergency where the sliding doors on the northeast wall of the Fabrication Area were marked as exit doors, and they were bolted together.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.36 E01
- Issued
- Apr 11, 2012
- Abate by
- Jul 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(e)(1): A side-hinged door was not used to connect any room to an exit route: a) On or about December 7, 2011, employer did not ensure that employees were protected from injuries during an emergency where the sliding door was not hinged.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.36 G01
- Issued
- Apr 11, 2012
- Abate by
- Jul 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(g)(1): The ceiling of an exit route was not at least seven feet six inches (2.3 m) high: A) On or about December 7, 2011, employer did not ensure that employees were protected from injuries during an emergency where the exit door was not at least seven feet six inches (2.3 m) high. The door was five feet high with an exit sign on it.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C05 II D
- Issued
- Apr 11, 2012
- Abate by
- Apr 16, 2012
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s): (a) On or about December 7, 2011, employer did not ensure that employees were protected from electrical hazards while using a compressor that was tagged out where the tag did not indentify the person that applied the tag.
Recent events (2)
- — I (S) $0
- — Z (S) $2100
1910.179 H01 III
- Issued
- Apr 11, 2012
- Abate by
- Apr 16, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.179(h)(1)(iii): The sheaves in the bottom block were not equipped with closefitting guards that prevented ropes from becoming fouled when the block was lying on the ground with ropes loose: a) On or about December 7, 2011, employer did not ensure that employees were protected from unsafe loads while hoisting loads with the middle crane where the wire rope guards were damaged and not attached adequately to the block.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.179 J02
- Issued
- Apr 11, 2012
- Abate by
- Apr 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2): The items listed in subparagraphs (j)(2)(i)-(vii) were not inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, and all deficiencies were not carefully examined and a determination made as to whether they constituted a safety hazard: a) On or about December 7, 2011, employer did not ensure that employees were protected from unsafe loads while hoisting loads with the middle crane where the wire rope guards were not inspected and repaired prior to using the crane.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 H02 V
- Issued
- Apr 11, 2012
- Abate by
- Apr 16, 2012
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.179(h)(2)(v): Rope clips attached with U-bolts did not have the U-bolts on the dead or short end of the rope: a) On or about December 7, 2011, employer did not ensure that employees were protected from unsafe loads while hoisting loads with the south yard crane where the wire rope was clipped with the U-bolt (saddle) on the dead end.
Recent events (2)
- — I (S) $0
- — Z (S) $2100
1910.179 H03
- Issued
- Apr 11, 2012
- Abate by
- May 23, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.179(h)(3): A load was supported by more than one part of rope but the tension in the parts was not equalized: a) On odr about December 7, 2011, employer did not ensure that employees were protected from unsafe loads from the crane while hoisting loads with the middle crane and the yard crane where the lower blocks were not level.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.179 L03 III D
- Issued
- Apr 11, 2012
- Abate by
- Apr 16, 2012
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.179(l)(3)(iii)(d): Pendant control stations were not kept clean, and/or their function labels were not kept legible: a) On or about December 7, 2011, employer did not ensure that employees were protected from unsafe loads while hoisting loads with the wall crane on the east-end of the Fabrication Areqa where the pendant was marked.
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
1910.253 E03 II C 3
- Issued
- Apr 11, 2012
- Abate by
- Apr 16, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.253(e)(3)(ii)(C)(3): Flashback protection was not provided by an approved device that would prevent flame from passing into the fuel gas system: a) On or about December 7, 2011, employer did not ensure that employees were protected from burn and explosion hazards while using the hand torches to cut and weld without flashback arrestors.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.303 G01
- Issued
- Apr 11, 2012
- Abate by
- Apr 16, 2012
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) On or about December 7, 2011, employer did not ensure that employees were protected from electrical hazards during an emergency where sufficient access was not provided to permit ready operation. Miller welder was stored infront of switch #36 and materials stored in front of switches, #12, #15, and #16.
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
1910.304 G05
- Issued
- Apr 11, 2012
- Abate by
- Apr 16, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The paths to ground from circuits, equipment, and enclosures were not permanent, continuous, and effective: a) On or about December 7, 2011, employer did not ensure that employees were protected from electrical injuries while using an electrical extension cord to energize the grinder where the plug of the electrical cord did not have a ground prong.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.334 A02 II
- Issued
- Apr 11, 2012
- Abate by
- Apr 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: a) On or about December 7, 2011, employer did not ensure that employees were protected from electrical hazards while using a grinder connected to an extension cord where the cord was damaged and not taken out of service.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Apr 11, 2012
- Abate by
- Jul 25, 2012
- Penalty
- Initial $5,600 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded: a) On or about December 7, 2011, employer did not ensure that employees were protected from amputation hazards while working with and near the following machines where they did not have guards on the point of operation: 1) Ellis Mitre Band Saw, not fully guarded (12 inches exposed). 2) Buffalo Drills (five drills in a row) not guarded. 3) Metal Cut Chop Saw, did not have adequate guarding on the blade. MIDWEST FABRICATON & STEEL, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD, 29 CFR 1910.212(a)(3)(ii), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 315019679, CITATION NUMBER 2, ITEM NUMBER 1, ISSUED ON 5/27/2011. THIS CITATION BECAME A FINAL ORDER ON 6/21/2011.
Recent events (2)
- — I (R) $2800
- — Z (R) $5600
1910.303 F02
- Issued
- Apr 11, 2012
- Abate by
- Apr 25, 2012
- Penalty
- Initial $5,600 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) On or about December 7, 2011. employer did not ensure that employees were protected from electrical injuries while working with and near the following electrical switches that were not marked to indicate their purpose: 1) Fabrication Area, fan switch was not labeled. 2) Drill Line Area, main switch for DNC Machine was not labeled. 3) Drill Line Area, main switch for main for all operations in the room was not labeled. 4) Drill Line Area, main switch for saw was not labeled. 5) Fabrication Area, switches for Miller Welders were not labeled. 6) Fabrication Area, switch for 50 hp Crusher was not labeled. MIDWEST FABRICATON & STEEL, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD, 29 CFR 1910.303(f)(2), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 315019679, CITATION NUMBER 1, ITEM NUMBER 4, ISSUED ON 5/27/2011. THIS CITATION BECAME A FINAL ORDER ON 6/21/2011.
Recent events (2)
- — I (R) $2800
- — Z (R) $5600
1910.305 B01 II
- Issued
- Apr 11, 2012
- Abate by
- Apr 16, 2012
- Penalty
- Initial $4,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) On or about December 7, 2011, employer did not ensure that employees were protected from electrical injuries while plugging in an electrical extension cord which was connected to a compressor where the metal receptacle box had a missng knock-out. MIDWEST FABRICATON & STEEL, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD, 29 CFR 1910.305(b)(1)(ii), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 315019679, CITATION NUMBER 2, ITEM NUMBER 3, ISSUED ON 5/27/2011. THIS CITATION BECAME A FINAL ORDER ON 6/21/2011.
Recent events (2)
- — I (R) $0
- — Z (R) $4200
1910.305 G02 III
- Issued
- Apr 11, 2012
- Abate by
- May 9, 2012
- Penalty
- Initial $4,200 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) On or about December, 7, 2011, employer did not ensure that employees were protected from electrical hazards while working with and near the following machines where the electrical cords did not have strain relief: 1) Mitre Band Saw Serial # 16051440 2) Metal Puncher 3) Fan in Drill Line Area MIDWEST FABRICATON & STEEL, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD, 29 CFR 1910.305(g)(2)(iii), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 315019679, CITATION NUMBER 2, ITEM NUMBER 4, ISSUED ON 5/27/2011. THIS CITATION BECAME A FINAL ORDER ON 6/21/2011.
Recent events (2)
- — I (R) $2100
- — Z (R) $4200
More inspections at Midwest Fabrication & Steel, INC.
View Midwest Fabrication & Steel, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332313)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331102772.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.