OSHA Inspection: TYMEX PLASTICS INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of TYMEX PLASTICS INC. in 5300 HARVARD AVE, CLEVELAND, OH 44105 (NAICS 325991). OSHA activity number 331109603.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tymex Plastics INC. — free Get an email when a new federal OSHA severe-injury report for Tymex Plastics INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TYMEX PLASTICS INC.
Site address
5300 HARVARD AVE
City
CLEVELAND
State
OH
ZIP
44105
Mailing
5300 HARVARD AVE, CLEVELAND, OH 44105
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325991
Employees
28
Ownership type
A

3 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 6, 2012
Abate by
Jun 27, 2012
Penalty
Initial $2,800 · Current $1,820 Reduced
29 CFR 1910.95(c)(1):     The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:    a. An employee working near the grinder was exposed to noise on or about 1/25/12. The employee had a time weighted average of 87.6 dBA and a dose of 71.78% which is above the action level for hearing conservation program implementation. The total sampling time was 442 minutes with the remaining 38 minutes considered as zero exposure.     b. An employee working near the grinder was exposed to noise on or about 1/25/12. The employee had a time weighted average of 88.9 dBA and a dose of 86.30% which is above the action level for hearing conservation program implementation. The total sampling time was 440 minutes with the remaining 40 minutes considered as zero exposure.    The company did not develop and implement a hearing conservation program.
Recent events (2)
  • — I (S) $1820
  • — Z (S) $2800

1910.157 E02

Other-than-serious 1 instance 3 exposed
Issued
Apr 6, 2012
Abate by
Apr 27, 2012
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.157(e)(2):     Portable fire extinguishers were not visually inspected at least monthly:    Portable fire extinguishers throughout the facility were not visually inspected on a monthly basis.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2100

1910.242 B

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 6, 2012
Abate by
Apr 27, 2012
Penalty
Initial $3,500 · Current $2,275 Reduced
29 CFR 1910.242(b):     Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    Company employees were using compressed air to clean floors. Compressed air greater than 30 psi was used for cleaning purposes.