HARRISON, OH —
OSHA Inspection: HEARTLAND ENGINEERED PRODUCTS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HEARTLAND ENGINEERED PRODUCTS, LLC in 355 INDUSTRIAL DR., HARRISON, OH 45030 (NAICS 332312). OSHA activity number 331904318.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HEARTLAND ENGINEERED PRODUCTS, LLC
- Site address
- 355 INDUSTRIAL DR.
- City
- HARRISON
- State
- OH
- ZIP
- 45030
- Mailing
- 355 INDUSTRIAL DR., HARRISON, OH 45030
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 28
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 I
- Issued
- Feb 2, 2012
- Abate by
- Mar 3, 2012
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) There was no written energy control (lockout) program. (b) There were no documented procedures for equipment with multiple energy sources, such as, but not limited to, the hydraulic presses, the hydraulic press brakes, the horizontal band saws and the beam line detailing all the energy sources, such as electrical, hydraulic, pneumatic and gravity, and what the control measures are to be taken for each source.
Recent events (2)
- — I (S) $3500
- — Z (S) $3500
1910.147 C06 I
- Issued
- Feb 2, 2012
- Abate by
- Mar 3, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: (a) There had not been any periodic or at least annual inspection of the energy control (lockout) procedures with records kept in the last calendar year.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.147 C07 I
- Issued
- Feb 2, 2012
- Abate by
- Mar 3, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) The Hyd-Mech saw operator was not trained as an authorized employee for tasks, such as, but not limited to, saw blade changes where there is the hazard of accidental activation or start-up.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.147 D04 I
- Issued
- Feb 2, 2012
- Abate by
- Mar 3, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) On or about January 26, 2012, the saw blade was changed on the Hyd-Mech S23A (s/n XA0601172) horizontal band saw and the main power disconnect was shut off, but not locked out.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.212 A01
- Issued
- Feb 2, 2012
- Abate by
- Feb 17, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by ingoing nip points, moving parts, etc.: (a) The Hyd-Mech S23A horizontal band saw (s/n XA0601172) was operated without the unused portion of the band saw blade being guarded.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
More inspections at Heartland Engineered Products, LLC
View Heartland Engineered Products, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331904318.