PARK FALLS, WI ·
OSHA Inspection: PROGRESSIVE CONVERTING, INC.
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of PROGRESSIVE CONVERTING, INC. in 200 NORTH FIRST AVENUE, PARK FALLS, WI 54552 (NAICS 322233). OSHA activity number 331905265.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROGRESSIVE CONVERTING, INC.
- Site address
- 200 NORTH FIRST AVENUE
- City
- PARK FALLS
- State
- WI
- ZIP
- 54552
- Mailing
- 200 NORTH FIRST AVENUE, PARK FALLS, WI 54552
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322233
- Employees
- 12
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C06 I
- Issued
- Feb 28, 2012
- Abate by
- Mar 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Throughout the facility; The employer did not conduct periodic inspection of energy control procedures on equipment, such as, but not limited to: (1) S-8 Sheeter (2) S-8 Ream Wrapper Sealer (3) S-8 Ream Labeler
Recent events (1)
- · Z (O) $0
1910.1200 E01 I
- Issued
- Feb 28, 2012
- Abate by
- Mar 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present using an identity that was referenced on the appropriate material safety data sheet: a) Administrative office/production desk; A list of known chemicals and substance used on site was not developed and maintained where employees were exposed to chemical, such as, but not limited to adhesives and lubricants.
Recent events (1)
- · Z (O) $0
More inspections at Progressive Converting, INC.
View Progressive Converting, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 322233)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331905265.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.