Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KRIEB ROOFING & SIDING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KRIEB ROOFING & SIDING LLC in 31 CALDWELL DRIVE, WEST SENECA, NY 14224 (NAICS 238160). OSHA activity number 331907899.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Krieb Roofing & Siding LLC — free Get an email when a new federal OSHA severe-injury report for Krieb Roofing & Siding LLC is published. One employer, no account, unsubscribe in one click.
Site address
31 CALDWELL DRIVE
City
WEST SENECA
State
NY
ZIP
14224
Mailing
12275 BLOSSOM LEA DRIVE, ALDEN, NY 14004
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 22, 2012
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1926.451(e)(1):     When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.    a)  On or about 2/1/12 at a new house construction project located at 31 Caldwell Drive, West Seneca, New York; employees installing asphalt shingles on a new house were using a ladder jack scaffold to perform work and access the back of the house. The ladders supporting the scaffold were used as access causing the employees to climb around the platform.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3000

1926.451 G01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 22, 2012
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1926.451(g)(1)(i):     Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:    a)  On or about 2/1/12 at a new house construction project located at 31 Caldwell Drive, West Seneca, New York; employees installing asphalt shingles on a new house were using a ladder jack scaffold to apply shingles and access the roof. Employees were not using a personal fall arrest system.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3000

1926.501 B13

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 22, 2012
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1926.501(b)(13):     Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor  did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.      a)  On or about 2/1/12 at a new house construction project located at 31 Caldwell Drive, West Seneca, New York; employees installing asphalt shingles on a new house with a piitch of approximately 9/12 and eave heights up to approximately 22 feet. The was no fall protection, in complete fall protection in place.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3000

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 22, 2012
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1926.1053(b)(1):     Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    a) On or about 2/1/12 at a new house construction project located at 31 Caldwell Drive, West Seneca, New York; employees installing asphalt shingles on a new house were accessing the roof using an extension ladder placed under the soffit then climbing around and over the eaves.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3000

View Krieb Roofing & Siding LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331907899.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.