OSHA Inspection: ADM GRAIN COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ADM GRAIN COMPANY in 4410 W MILITARY, FREMONT, NE 68025 (NAICS 493130). OSHA activity number 331911461.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ADM Grain Company for free Get an email when a new federal OSHA severe-injury report for ADM Grain Company is published. One employer, no account, unsubscribe in one click.
Establishment
ADM GRAIN COMPANY
Site address
4410 W MILITARY
City
FREMONT
State
NE
ZIP
68025
Mailing
4410 W MILITARY, FREMONT, NE 68025
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493130
Employees
8
Ownership type
Private (A)

5 citations on file for this inspection.

1910.215 B09

Serious Gravity 5 1 exposed
Issued
Mar 20, 2012
Abate by
Apr 4, 2012
Penalty
Initial $4,400 · Current $5,300
29 CFR 1910.215(b)(9):     The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:                                                       In maintenance shop area of the facility the employer is failing to ensure the bench grinders tongue guard was adjusted to within one fourth inch of the outer surface of the abrasive wheel.   The periphery of the wheel was 2 inch from the bottom of the tongue guard on the Albertson & Company Sioux model SKC65AB48A.
Recent events (2)
  • · I (S) $5300
  • · Z (S) $4400

1910.253 B04 III

Other-than-serious 1 instance 1 exposed
Issued
Mar 20, 2012
Abate by
Apr 4, 2012
Penalty
Initial $5,500 · Current $5,500
29 CFR 1910.253(b)(4)(iii):     29 CFR 1910.253(b)(4)(iii):      Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects:    On the South Wall of the maintenance shop the employer is failing to ensure that gas cylinders stored in the maintenance area were secured to prevent tipping and falling.
Recent events (2)
  • · I (O) $5500
  • · Z (S) $5500

1910.304 B03 I

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 20, 2012
Abate by
Apr 4, 2012
Penalty
Initial $3,300 · Current $5,400
29 CFR 1910.304(b)(3)(i):     All 125 Volt receptacles installed in a bathroom will have a ground-fault circuit-interrupter (GFCI) protection for personnel.     In the bathroom of the facility adjacent to the employee break room of the employer was failing to ensure that receptacles were equipped with a GFCI.
Recent events (2)
  • · I (S) $5400
  • · Z (S) $3300

1910.305 G01 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 20, 2012
Abate by
Apr 4, 2012
Penalty
Initial $3,300 · Current $5,400
29 CFR 1910.305(g)(1)(iv):     Flexible cords and cables shall not be ran through holes in the floors, doorway, windows or similar openings.    At the West Pit Controls of the elevator the employer is failing to ensure that flexible cords are not run through floors, doors or windows.
Recent events (2)
  • · I (S) $5400
  • · Z (S) $3300

1910.253 B02 II

Serious Gravity 5 1 exposed
Issued
Mar 20, 2012
Abate by
Apr 4, 2012
Penalty
Initial $27,500 · Current $7,000 Reduced
29 CFR 1910.253(b)(2)(ii):     Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior:    On the South Wall of the Maintenance Building the employer is failing to ensure that oxygen cylinders are stored in location, at least 20 feet (6.1m) from highly combustible materials such as Acetylene and petroleum fuel gas cylinders.    ADM Grain Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.253(b)(2)(ii), which was contained in OSHA inspection number 312156367, citation 2, item number 1, and was affirmed as final on January 23, 2009, with respect to  a work place located at 2122 Navigation Blvd. Corpus Christi, TX 78402
Recent events (2)
  • · I (S) $7000
  • · Z (R) $27500

View ADM Grain Company's full OSHA safety record →