TRAVIS AFB, CA —
OSHA Inspection: U.S. AIR FORCE 60TH AERIAL PORT SQUADRON
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of U.S. AIR FORCE 60TH AERIAL PORT SQUADRON in 90 RAGSDALE STREET BLDG. 977, TRAVIS AFB, CA 94535 (NAICS 928110). OSHA activity number 331917328.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. AIR FORCE 60TH AERIAL PORT SQUADRON
- Site address
- 90 RAGSDALE STREET BLDG. 977
- City
- TRAVIS AFB
- State
- CA
- ZIP
- 94535
- Mailing
- 540 AIRLIFT DRIVE BLDG. 381 WING 2-C, TRAVIS AFB, CA 94535
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 107
- Ownership type
- D
Citations
6 citations on file for this inspection.
1910.23 E01
- Issued
- Jul 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level: a. Bldg. 977, exit near bay closest to wood shop - Noted on or about 1/20/12, the top railings of a stairway were not constructed to extend the full length of the stairs.
Recent events (1)
- — Z (S) $0
1910.37 A04
- Issued
- Jul 30, 2012
- Abate by
- Sep 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: a. Bldg. 977, Bay 1 - Noted on or about 1/20/12, the designated exit next to Bay 1 had a broken self-closing mechanism and the exit door could not easily be closed shut.
Recent events (1)
- — Z (S) $0
1910.146 C05 II B
- Issued
- Jul 30, 2012
- Abate by
- Sep 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(5)(ii)(B): When an entrance cover was removed, the opening was not promptly guarded by a railing, temporary cover, or other temporary barrier that would prevent an accidental fall through the opening and that would protect each employee a. Bldg. 977, Bay 15 - Noted on or about 1/20/12, a permit required confined space pallet pit (12-13 ft. deep) was not secured as required and left open with a ladder sticking out. This condition has existed since 12/19/11 when an entry was made in order to repair a scale.
Recent events (1)
- — Z (S) $0
1910.146 D09
- Issued
- Jul 30, 2012
- Abate by
- Sep 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(d)(9): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces to rescued employees, and for preventing unauthorized personnel from attempting a resuce: (a) Bldg. 977 - Noted on or about 1/20/12, the employer did not develop written procedures for summoning rescue and emergency services or for rescuing entrants from permit-required confined spaces.
Recent events (1)
- — Z (S) $0
1910.212 A01
- Issued
- Jul 30, 2012
- Abate by
- Sep 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by: (a) Bldg. 977, Wood Shop - Noted on or about 1/20/12, the Rockwell drill press, MD. 15-017, serail #1371055, was not guarded at the point of operation.
Recent events (1)
- — Z (S) $0
1910.242 B
- Issued
- Jul 30, 2012
- Abate by
- Sep 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) Wood Shop, Bldg. 977 - Noted on or about 1/23/12, an employee used an air hose to remove wood dust from their clothing. According to the employer the pressure in the air line is 125 psi; a pressure reducing nozzle attached to the end of the line reduces this pressure. Compressed air, regardless of the pressure in the line, should never be used for cleaning work clothes.
Recent events (1)
- — Z (S) $0
More inspections at U.S. AIR Force 60TH Aerial Port Squadron
View U.S. AIR Force 60TH Aerial Port Squadron's full OSHA safety record →
More inspections in this industry (NAICS 928110)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331917328.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.