Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADAMS THERMAL SYSTEMS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ADAMS THERMAL SYSTEMS, INC. in 47920 FIFTH STREET, CANTON, SD 57013 (NAICS 333415). OSHA activity number 332426600.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Adams Thermal Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Adams Thermal Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
47920 FIFTH STREET
City
CANTON
State
SD
ZIP
57013
Mailing
47920 FIFTH STREET, CANTON, SD 57013
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333415
Employees
700
Ownership type
A

7 citations on file for this inspection.

1910.132 D01 I

Serious Gravity 5 2 instances 2 exposed
Issued
Aug 6, 2012
Abate by
Sep 30, 2013
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment:    (a) On or about February 22, 2012, and at times prior, in the powder coat spray booth, also known as the SureCoat line by Nordson, at Adams Thermal Systems, Inc. in Canton, South Dakota, an employee was working with bare hands to operate a hood sprayer to apply powdered coating to thermal systems as they pass through the spray booth.      (b) On or about February 22, 2012, and at times prior, in the powder coat spray booth, also known as the SureCoat line by Nordson, at Adams Thermal Systems, Inc. in Canton, South Dakota, an employee was working with a hood sprayer to apply powdered coating to thermal systems as they pass through the spray booth without appropriate eye protection as the eye protection selected still allowed the black powder coat to get around the eyes.
Recent events (3)
  • — F (S) $5000
  • — C (S) $5000
  • — Z (S) $5000

1910.132 D01 III

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 6, 2012
Abate by
Sep 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1)(iii): The employer did not select PPE that properly fit each affected employee:    (a) On or about February 22, 2012, and at times prior, in the powder coat booth, also known as the SureCoat line by Nordson, at Adams Thermal Systems, Inc. in Canton, South Dakota, an employee was working with a hood sprayer to apply powdered coating to thermal systems as they pass through the spray booth with a Tyvek suit that was too small for the employee, exposing skin to the black powder coat.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1904.40 A

Other-than-serious 1 instance 700 exposed
Issued
Aug 6, 2012
Abate by
Sep 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours:    (a) On or about June 4, 2012, and at times after, the employer failed to provide copies of the injury and illness records to an authorized representative for years 2009, 2010 and 2011.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.95 D01

Other-than-serious 1 instance 700 exposed
Issued
Aug 6, 2012
Abate by
Sep 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program:    (a) On or about February 21, 2012, and at times prior, Adams Thermal Systems, Inc. had not developed or implemented a monitoring program with a sampling strategy designed to evaluate the efficacy of the hearing conservation program or hearing protection.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.134 H01 I

Other-than-serious 1 instance 2 exposed
Issued
Aug 6, 2012
Abate by
Sep 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(1)(i): Respirators issued for the exclusive use of an employee were not cleaned and disinfected as often as necessary to be maintained in a sanitary condition:    (a) On or about February 22, 2012, and at times prior, employees working in the powder coat spray booth at Adams Thermal Systems, Inc. in Canton, South Dakota were required to wear tight-fitting half-face air-purifying respirators that were not maintained in a sanitary condition as employees began their shift.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.1000 A02

Other-than-serious 1 instance 2 exposed
Issued
Aug 6, 2012
Abate by
Sep 30, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 9135

29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of Total Dust, Particulate Not Otherwise Regulated (PNOR), listed in Table Z-1 in excess of the 8-hour Time-Weighted Average concentration of 15 mg/m3:     (a) On or about February 22, 2012, and at times prior, an employee working in the powder coat spray booth at Adams Thermal Systems located at 47920 Fifth Street, in Canton, South Dakota, was exposed to Total Dust, PNOR at levels found by OSHA to be in excess of the OSHA PEL at a Time-Weighted Average (TWA) of up to approximately 59.9 mg/m3, at approximately four times the PEL.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.1000 E

Other-than-serious 1 instance 2 exposed
Issued
Aug 6, 2012
Abate by
Sep 30, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 9135

29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):    (a) On or about February 22, 2012, and at times prior, an employee working in the powder coat spray booth at Adams Thermal Systems, Inc. located at 47920 Fifth Street, in Canton, South Dakota, was exposed to Total Dust, PNOR at levels found by OSHA to be in excess of the OSHA PEL at a Time-Weighted Average (TWA) of up to approximately 59.9 mg/m3, at approximately four times the PEL.      Potentially feasible methods of abatement may include, among others:     1. Conducting a complete evaluation of ventilation system(s), and/or;    2. Prohibiting the partial entry of employees into the spray booth while spraying.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Adams Thermal Systems, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332426600.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.