Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R. SABEE COMPANY, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of R. SABEE COMPANY, LLC in 1718 W 8TH STREET, APPLETON, WI 54914 (NAICS 322291). OSHA activity number 332429133.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R. Sabee Company, LLC — free Get an email when a new federal OSHA severe-injury report for R. Sabee Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1718 W 8TH STREET
City
APPLETON
State
WI
ZIP
54914
Mailing
1718 W 8TH STREET, APPLETON, WI 54914
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322291
Employees
52
Ownership type
A

13 citations on file for this inspection.

1910.141 A03 I

Serious Gravity 5 1 instance 50 exposed
Issued
May 8, 2012
Abate by
May 22, 2012
Penalty
Initial $2,975 · Current $2,000 Reduced
29 CFR 1910.141(a)(3)(i):     Places of employment were not kept clean to the extent that the nature of the work allowed:    a)    Cellulose dust was accumulated on the floor, ductwork, wall, transformer and FP 9 Hammermill housing.    ABATEMENT CERTIFICATION AND ABQATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2975

1910.157 E03

Serious Gravity 5 1 instance 50 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $2,975 · Current $2,000 Reduced
29 CFR 1910.157(e)(3):     Portable fire extinguishers were not subjected to an annual maintenance check:    a)    Fire extinguishers had not undergone an annual inspection since 2003 or before.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2975

1910.157 F02

Serious Gravity 5 1 instance 50 exposed
Issued
May 8, 2012
Abate by
Jun 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(f)(2):     Portable fire extinguishers were not hydrostatically tested within the intervals specified in Table L1:    a)    Carbon dioxide extinguisher in the machine shop had not been tested within the last five years. It was last serviced in October, 2006    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.184 H05 III

Serious Gravity 5 1 instance 10 exposed
Issued
May 8, 2012
Abate by
May 18, 2012
Penalty
Initial $2,380 · Current $1,600 Reduced
29 CFR 1910.184(h)(5)(iii):     Natural or synthetic fiber rope sling(s) with broken or cut fibers were not immediately removed from service:    a)    Damaged nylon slings were available for use in the #303 steel parts building.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $1600
  • — Z (S) $2380

1910.184 I01

Serious Gravity 5 1 instance 1 exposed
Issued
May 8, 2012
Abate by
May 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.184(i)(1):     Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material:    a)    Synthetic web sling in machine shop was not marked with rated capacities.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 12 instances 25 exposed
Issued
May 8, 2012
Abate by
Dec 7, 2012
Penalty
Initial $4,900 · Current $3,400 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a)    W.F. Wells horizontal saw had aproximately 7" to the right and 9" to the left of the unused portion of the blade exposed.     b)    Machine TL42 had an exposed knife cut roll. Employee picks within 17" of roll.    c)    Machine TL42 had inrunning nip points on the unwind belts.    d)    Machine TL22 had exposed knife cut roll.     e)    Machine TL6 cutoff roll needs guarding. Aprox. 9" to ingoing nip from yellow side guard.    f)    Machine TL6 wire web ingoing nip point was not adequately guarded approximately 10" from control panel.    g)    Machine FP9 outfeed product transfer roller ingoing nip point was unguarding aproximately 7" from frame to roller. There was an approximately 18" x 29" opening in guard where pads drop into container.    h)    Machine TL33 cut off roll was not adequately guarded.    i)    Machine SL11, side guarded lacking for ingoing roll nips.    j)    Machine TL24, steel emboss rolls ingoing nip point was not adequately guarded.    k)    Machine FP8, frontside incline vaccum belt ingoing nip point under molding section was unguraded. Aprox. 3" from clyinder frame to nip point.    l)    Wells & Sons horizontal saw with exposed portions of unused saw blade. Aprox. 5" on right side & 3" on left side.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $3400
  • — Z (S) $4900

1910.212 A02

Serious Gravity 5 2 exposed
Issued
May 8, 2012
Abate by
Dec 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(2):     Machine guard(s) on machine(s) were so installed that they offered accident hazards in themselves:    a)    Machine SL11 had damaged mesh wiring on swing up guard. Machine operated prior week per company.    b)    Machine TL24 had damaged wire mesh swing up and side guards.    c)    Machine FP9 hammermill housing door had a broken hinge with door hanging open.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 1 exposed
Issued
May 8, 2012
Abate by
Aug 7, 2012
Penalty
Initial $2,975 · Current $2,000 Reduced
29 CFR 1910.219(d)(1):     Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a)    GI fan and motor in boiler room without guard on pulley.    b)    Machine SL11 drive pulley exposed approximately 7" from guard.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2975

1910.219 E03 I

Serious Gravity 5 1 exposed
Issued
May 8, 2012
Abate by
Aug 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i):     Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):    a)    GI fan and motor in boiler room without guard on belt and pulley.    b)    Machine SL11 drive belts and pulley exposed approximately 7" from guard.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 F03

Serious Gravity 5 3 instances 10 exposed
Issued
May 8, 2012
Abate by
Aug 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.219(f)(3):     Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed:    a)    TL19 chain and sprocket were not enclosed or guarded. Aprox. 20" from emergency stop to chains and sprockets.    b)    TL19 backside of machine drive chain and sprocket were not enclosed or fully guarded.  Approximately 7" from guard to unwind.    c)    ABC Palletizer chain and sprocket drive was not enclosed or adequately guarded aprox. 6" from frame.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 I02

Serious Gravity 5 1 exposed
Issued
May 8, 2012
Abate by
Aug 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.219(i)(2):     Revolving surfaces of shaft coupling(s) were not covered by a safety sleeve:    a)    FP8 backside drive unit had partially exposed coupling. Aprox 2" from top guard and 10" from side guard.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F02

Other-than-serious 2 instances 1 exposed
Issued
May 8, 2012
Abate by
Aug 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2):     Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    a)    Circuit breaker panels in the machine shop did not have all of the circuits labeled.    b)    Circuit breaker panel in compressor room did not have all of the circuits labeled.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.334 A02 II

Other-than-serious 2 instances 1 exposed
Issued
May 8, 2012
Abate by
May 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii):     There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:    a)    Extension cord for pedestal fan cooling motors in FP9 hammermil housing was damaged.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)