TROY, OH —
OSHA Inspection: PEAK FOODS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PEAK FOODS LLC in 1903 W. MAIN STREET, TROY, OH 45373 (NAICS 311511). OSHA activity number 332429166.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PEAK FOODS LLC
- Site address
- 1903 W. MAIN STREET
- City
- TROY
- State
- OH
- ZIP
- 45373
- Mailing
- 1903 W. MAIN STREET, TROY, OH 45373
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311511
- Employees
- 55
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 II
- Issued
- Aug 3, 2012
- Abate by
- Aug 24, 2012
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: (a) The machine specific energy control procedure for locking out Compressor #2 were incomplete, in that they did not include a specific statement as to the intended use of the procedures, specific procedural steps for placing and removing lockout devices, and specific requirements for testing the equipment to verify the effectiveness of the energy isolation measures. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.147 C06 I
- Issued
- Aug 3, 2012
- Abate by
- Aug 24, 2012
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: (a) There was no periodic inspection of the energy control program to include a review of each machine's energy control procedures, as well as a review between the inspector and each authorized employee, of that employees responsibilities under the energy control program, including observing the authorized employees actually performing servicing and/or maintenance activities on machines or equipment, such as the compressors. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.147 C07 I
- Issued
- Aug 3, 2012
- Abate by
- Aug 24, 2012
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) Maintenance employees working on Compressor #2, were not adequately trained on the energy control program, in that they did not isolate and lock out the oil return valve. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.147 D03
- Issued
- Aug 3, 2012
- Abate by
- Aug 24, 2012
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) On or about Feb 8, 2012, employees were working on Compressor #2, failed to turn off the oil return valve, as directed by SOP C-01/C-02/C-03/C-4. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1910.147 D04 I
- Issued
- Aug 3, 2012
- Abate by
- Aug 24, 2012
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees: (a) On or about Feb 8, 2012, employees were working on Compressor #2, failed to attach a lock to the oil return valve, as directed by SOP C-01/C-02/C-03/C-4. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.212 A01
- Issued
- Aug 3, 2012
- Abate by
- Aug 24, 2012
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.: (a) Employees operating the MSC Horizontal Band Saw, were exposed to 22 inches of unguarded blade. (b) Employees operating the Wilton Vertical Band Saw, were exposed to 19 inches of unguarded blade. (c) Employees operating the machine lathe in the maintenance shop, were exposed to the unguarded chuck. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
More inspections at Peak Foods LLC
View Peak Foods LLC's full OSHA safety record →
More inspections in this industry (NAICS 311511)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332429166.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.