TROY, OH —
OSHA Inspection: PEAK FOODS LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PEAK FOODS LLC in 1903 W. MAIN STREET, TROY, OH 45373 (NAICS 311511). OSHA activity number 346911969.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PEAK FOODS LLC
- Site address
- 1903 W. MAIN STREET
- City
- TROY
- State
- OH
- ZIP
- 45373
- Mailing
- 1903 W. MAIN STREET, TROY, OH 45373
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311511
- Employees
- 92
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II C
- Issued
- Nov 16, 2023
- Abate by
- Feb 6, 2024
- Penalty
- Initial $10,938 · Current $6,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C):The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: (c) Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and a) On or about August 11, 2023, the documented machine-specific procedures for the High Speed Doors (Rytec/ Rite Hite), which identified electronic and mechanical energy sources, did not contain specific procedural steps for shutting down, isolating, blocking and securing the electric and mechanical energy sources. The procedure did not list steps to remove locks and return the equipment to service.
Recent events (2)
- — I (S) $6500
- — Z (S) $10938
1910.147 C06 I
- Issued
- Nov 16, 2023
- Abate by
- Feb 6, 2024
- Penalty
- Initial $10,938 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) On or about August 16, 2023, the employer did not ensure that a periodic inspection of the energy control procedures such as but not limited to the Rytech High-Speed Door, located in the s-curve near the freezer, had been completed at least annually.
Recent events (2)
- — I (S) $0
- — Z (S) $10938
1910.147 D
- Issued
- Nov 16, 2023
- Abate by
- Dec 6, 2023
- Penalty
- Initial $10,938 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: Each employee was not required to: (1) prepare for shutdown, (2) turn off and shut down the machines, (3) physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the electric and pneumatic energy sources, (4) affix lockout or tagout devices to each energy-isolating device, (5) ensure that all potentially hazardous stored or residual energy is relieved, disconnected, restrained, and otherwise rendered safe, (6) verify the effectiveness of energy isolation. a) On or about August 11, 2023, the employer did not ensure that (d)(1) through (d)(6) was followed by authorized employees performing maintenance work on the Rytech high speed door by securing the electrical and mechanical energy sources for the door prior to starting work. Employees were exposed to caught-in hazards associated with the movement of the drive chain assembly, chain and sprocket when the door was activated.
Recent events (2)
- — I (S) $0
- — Z (S) $10938
More inspections at Peak Foods LLC
View Peak Foods LLC's full OSHA safety record →
More inspections in this industry (NAICS 311511)