OSHA Inspection: TRIAD CAPITAL GROUP, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TRIAD CAPITAL GROUP, LLC in 13676 N STATION ROAD, COLUMBIA STATION, OH 44028 (NAICS 332999). OSHA activity number 332793355.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Triad Capital Group, LLC — free Get an email when a new federal OSHA severe-injury report for Triad Capital Group, LLC is published. One employer, no account, unsubscribe in one click.
Site address
13676 N STATION ROAD
City
COLUMBIA STATION
State
OH
ZIP
44028
Mailing
13676 N STATION RD, COLUMBIA STATION, OH 44028
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
12
Ownership type
A

9 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 4 exposed
Issued
May 18, 2012
Abate by
Jun 18, 2012
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a) Triad Capital Group, LLC - Columbia Station, Ohio: On or about March 7, 2012, the employer did not assure that written energy control procedures were developed and implemented to control hazardous energy such as gravitational, mechanical, and pneumatic when employees were engaged in operations such as, but not limited to, die set-up activities on mechanical power presses.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
  • — F (S) $2100
  • — C (S) $4200
  • — Z (S) $4200

1910.217 D09 I

Serious Gravity 10 1 instance 4 exposed
Issued
May 18, 2012
Abate by
Jun 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.217(d)(9)(i): The employer did not establish a die setting procedure for mechanical power press(es) that would ensure compliance with 29 CFR 1910.217(b)(c):    a) Triad Capital Group, LLC - Columbia Station, Ohio: On or about March 7, 2012, the employer did not assure that written energy control procedures were developed and implemented to control hazardous energy such as gravitational, mechanical, and pneumatic when employees were engaged in operations such as, but not limited to, die set-up activities on mechanical power presses.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.217 B07 III

Serious Gravity 5 3 instances 4 exposed
Issued
May 18, 2012
Abate by
Jun 18, 2012
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.217(b)(7)(iii): A means of fixing the selection between off, inch, single stroke, and continuous was not capable of supervision by the employer:    a) Triad Capital Group, LLC - Columbia Station, Ohio: On or about February 6, 2012, the employer did not assure that the operating mode on the Bliss 28 press was capable of being set in a fixed position.  The operating mode could be changed by selector switch that was not capable of being secured in a fixed position and supervised by the employer, exposing employees to an amputation hazard.       b) Triad Capital Group, LLC - Columbia Station, Ohio: On or about February 28, 2012, the employer did not assure that the operating mode on the Rockford press was capable of being set in a fixed position.  The operating mode could be changed by a push button without being secured and supervised by the employer, exposing employees to amputation hazards.     c) Triad Capital Group, LLC - Columbia Station, Ohio: On or about February 6, 2012, the employer did not assure that the operating mode of the Minster 50 press was capable of being set in a fixed position and supervised by the employer.  The operating mode could be changed by a selector switch that was not capable of being secured in a fixed position and supervised by the employer, exposing employees to an amputation hazard.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
  • — F (S) $1500
  • — C (S) $3000
  • — Z (S) $3000

1910.217 C03 VII D

Serious Gravity 5 2 instances 4 exposed
Issued
May 18, 2012
Abate by
Jun 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.217(c)(3)(vii)(d): Two hand controls used with mechanical power press(es) were not fixed in position so that only a supervisor or safety engineer was capable of relocating the controls:    a) Triad Capital Group, LLC - Columbia Station, Ohio: On or about February 6, 2012, the employer did not assure the two hand control pedestal used to operate the Bliss 28 press was in a fixed position.  Employee(s) were exposed to amputation hazards in that the pedestal was not secured and could be moved and operated directly in adjacent to the hazard area.     b) Triad Capital Group, LLC - Columbia Station, Ohio: On or about February 27, 2012, the employer did not assure the two hand control pedestal used to operate the Warco press #100-2-54C was in a fixed position.  Employee(s) were exposed to amputation hazards in that the pedestal was not secured and could be moved and operated directly adjacent to the hazard area.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.217 C01 I

Serious Gravity 10 4 instances 4 exposed
Issued
May 18, 2012
Abate by
Jun 18, 2012
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es):    a) Triad Capital Group, LLC - Columbia Station, Ohio: On or about February 22, 2012, the employer did not provide and assure that the employees operating the Federal press (s/n 10-221) were protected from the point of operation.  Employees were exposed to amputation hazards while the press was operated in continuous mode.    b) Triad Capital Group, LLC - Columbia Station, Ohio: On or about February 22, 2012, the employer did not provide and assure that employees operating the Niagara E-60 were protected from the point of operation.  Employees were exposed to amputation hazards while the press was operated in continuous mode.    c) Triad Capital Group, LLC - Columbia Station, Ohio: On or about February 28, 2012, the employer did not provide and assure that employees operating the Rockford press were protected from the point of operation.  Employees were exposed to amputation hazards while the press was operated in continuous mode.    d) Triad Capital Group, LLC - Columbia Station, Ohio: On or about February 27, 2012, the employer did not provide and assure that employees operating the  Warco press #100-2-54C were protected from the point of operation.  Employees were exposed to amputation hazards while the press was operated in continuous mode.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
  • — F (S) $2100
  • — C (S) $4200
  • — Z (S) $4200

1910.217 C02 I A

Serious Gravity 10 1 instance 4 exposed
Issued
May 18, 2012
Abate by
Jun 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s)    a) Triad Capital Group, LLC - Columbia Station, Ohio: On or about February 6, 2012, the employer did not assure the point of operation guards being used on the Mister 50 press protected employees from amputation injuries.  The point of operation could be accessed from behind the press, exposing employee while performing tasks such as, but not limited to, cleaning scrap metal from the back of the press.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.219 C02 I

Serious Gravity 5 1 instance 2 exposed
Issued
May 18, 2012
Abate by
Jun 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:    a) Triad Capital Group, LLC - Columbia Station, Ohio: On or about March 7, 2012, horizontal shafting for the flywheel on the gray Bliss full revolution power press was not guarded.  Employees were exposed to the rotating parts when removing and replacing the parts bin stored directly under the unguarded shaft.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.217 E03

Serious Gravity 10 1 instance 4 exposed
Issued
May 18, 2012
Abate by
Jun 18, 2012
Penalty
Initial $4,200 · Current $0 Reduced
29 CFR 1910.217(e)(3): Original and continuing competence of personnel maintaining mechanical power press(es) was not insured:    a) Triad Capital Group, LLC - Columbia Station, Ohio: On or about March 7, 2012, the employer did not assure that employees who serviced mechanical power presses were trained to inspect and maintain mechanical power presses. The original and continuing competence of personnel servicing power presses was not maintained in that:  - Regular inspections of equipment and safeguards, including safeguards that prevent operators from inadvertently reaching into the hazard area of presses were not conducted and/or documented.    - Employees operated presses which were not guarded properly.  - Employees changed dies without die setting procedures and locking the machine out.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (3)
  • — F (S) $0
  • — C (S) $4200
  • — Z (S) $4200

1910.217 C03 IV D

Other-than-serious 1 instance 3 exposed
Issued
May 18, 2012
Abate by
Jun 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.217(c)(3)(iv)(d): Pullout device(s) on mechanical power press(es) were not visually inspected and checked for proper adjustment at the start of each operator shift, following a new die setup, and when operators were changed:    a) Triad Capital Group, LLC - Columbia Station, Ohio: On or about March 7, 2012, inspection records to assure proper adjustment of pull-out devices were not recorded at the start of each operator shift, when operators were changed, and/or following a die change.  Inspection records were not maintained for the Bliss and Roselle mechanical power presses.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Triad Capital Group, LLC's full OSHA safety record →