Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AIR CAPITAL STUCCO, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AIR CAPITAL STUCCO, LLC in 2501 N. 14TH AVE., DODGE CITY, KS 67801 (NAICS 238140). OSHA activity number 332803238.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AIR Capital Stucco, LLC — free Get an email when a new federal OSHA severe-injury report for AIR Capital Stucco, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2501 N. 14TH AVE.
City
DODGE CITY
State
KS
ZIP
67801
Mailing
4200 W. DOUGLAS, NEWTON, KS 67114
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.451 G01

Serious Gravity 5 2 instances 3 exposed
Issued
Apr 30, 2012
Abate by
May 21, 2012
Penalty
Initial $2,400 · Current $1,680 Reduced
29 CFR 1926.451(g)(1):     Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part.    A the jobsite located at 2501 N. 14th Ave, Dodge City KS:  Employees engaged in EIFS installation activities from a three tier tubular welded frame scaffold were exposed to fall hazards of approximately 18 feet and 12 feet to the ground as:    a) At the ladder access point no guardrailing or other equally effective means of fall protection was not provided.    b) The midrail was not fully in place on the second tier of the scaffold.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2400

1926.452 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 30, 2012
Penalty
Initial $2,400 · Current $1,680 Reduced
29 CFR 1926.452(c)(2):     Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.    At the jobsite located at 2501 N. 14th Ave., Dodge City KS:  Employees engaged in EIFS installation activities from a three tier tubular welded frame scaffold were exposed to scaffold collapse hazards in that all segments of the scaffold were not braced using cross, horizontal, diagonal or a combination of the aforementioned braces.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2400

View AIR Capital Stucco, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332803238.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.