On , OSHA opened a planned safety inspection of W.S. STEEL ERECTION, L.L.C. in 9238 N 1604 W, SAN ANTONIO, TX 78259 (NAICS 238120). OSHA activity number 333289981.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch W.S. Steel Erection, L.L.C. for free Get an email when a new federal OSHA severe-injury report for W.S. Steel Erection, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
9238 N 1604 W
City
SAN ANTONIO
State
TX
ZIP
78259
Mailing
P.O. BOX 593497, SAN ANTONIO, TX 78259
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
3
Ownership type
Private (A)

3 citations on file for this inspection.

1926.351 B03

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
May 31, 2012
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1926.351(b)(3): Cable lugs used to splice or connect welding cables one to another were not securely fastened together to give good electrical contact:    a) On or about March 20, 2012, and at times prior thereto, at this construction site, an employee was allowed to do electrical welding in which the connector of the welding cable lead was not securely fastened exposing him to an electrical hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4900

1926.351 B04

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
May 31, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.351(b)(4): Welding cable(s) in use were in need of repair:    a) On or about March 20, 2012, and at times prior thereto at this construction site, an employee was allowed to do electrical welding work with a cable lead that was damaged, inadequately repaired and had exposed bare conductors. This condition exposed the employees to an electrical hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 B02

Deleted Serious Gravity 1 1 exposed
Issued
May 31, 2012
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1926.451(b)(2): Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway was not at least 18 inches (46 cm) wide.    a) On or about March 20, 2012, and times prior thereto, at this construction site an employee was allowed to do steel erection work while standing on the toe guard system of a scissor lift without having both feet on the working platform at all times along the north east section of the construction building.