WESTERVILLE, OH —
OSHA Inspection: RODRIGUEZ CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RODRIGUEZ CONSTRUCTION LLC in 731 MILL CROSSING DRIVE, WESTERVILLE, OH 43081 (NAICS 238130). OSHA activity number 333295780.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RODRIGUEZ CONSTRUCTION LLC
- Site address
- 731 MILL CROSSING DRIVE
- City
- WESTERVILLE
- State
- OH
- ZIP
- 43081
- Mailing
- 1828 FOREST MAPLE LANE, COLUMBUS, OH 43229
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.404 F06
- Issued
- May 16, 2012
- Abate by
- May 23, 2012
- Penalty
- Initial $1,020 · Current $408 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent andcontinuous. a. On the second floor of the residential home where framing was performed, there were two extension cords used to provide power to portable tools such as, saws that did not have ground prongs thereby exposing employees to a contact hazard. b. At the back of the residential home being framed, there was an extension cord used to supply power to portable tools such as, saws that did not have a ground prong thereby exposing employees to a contact hazard.
Recent events (2)
- — I (S) $408
- — Z (S) $1020
1926.501 B13
- Issued
- May 16, 2012
- Penalty
- Initial $1,700 · Current $680 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet(1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provisionin paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it isinfeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets therequirements of paragraph (k) of 1926.502.Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fallprotection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complieswith 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. a. On the roof where employees were installing sheets of plywood, the employer did not provide or enforce the use of fall protection thereby exposing employees to a fall hazard.
Recent events (2)
- — I (S) $680
- — Z (S) $1700
1926.503 A01
- Issued
- May 16, 2012
- Abate by
- Jun 15, 2012
- Penalty
- Initial $1,700 · Current $680 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards. a. On the site where employees were framing a residential home, the employer did not provide fall protection training to employees working on the roof installing sheets of plywood thereby exposing employees to a fall hazard.
Recent events (2)
- — I (S) $680
- — Z (S) $1700
1926.1052 C01 II
- Issued
- May 16, 2012
- Abate by
- May 23, 2012
- Penalty
- Initial $1,020 · Current $408 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): One stairrail system along each unprotected side or edge.Note: When the top edge of a stairrail system also serves as a handrail, paragraph (c)(7) of this section applies. a. At the front of the residential home being built, the employer failed to install stairrails on the stairway to the second floor thereby exposing employees to a fall hazard.
Recent events (2)
- — I (S) $408
- — Z (S) $1020
More inspections at Rodriguez Construction LLC
View Rodriguez Construction LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333295780.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.