DANSVILLE, NY —
OSHA Inspection: GPM ASSOCIATES LLC FORBES PRODUCTS CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GPM ASSOCIATES LLC FORBES PRODUCTS CORP. in 10 FORBES ST., DANSVILLE, NY 14437 (NAICS 323118). OSHA activity number 333297489.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GPM ASSOCIATES LLC FORBES PRODUCTS CORP.
- Site address
- 10 FORBES ST.
- City
- DANSVILLE
- State
- NY
- ZIP
- 14437
- Mailing
- 10 FORBES ST., DANSVILLE, NY 14437
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323118
- Employees
- 97
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.106 D03 II A
- Issued
- Apr 24, 2012
- Penalty
- Initial $2,700 · Current $2,025 Reduced
General-duty citation text
29 CFR 1910.106(d)(3)(ii)(a): Metal cabinets constructed in the following manner shall be deemed to be in compliance. The bottom, top, door, and sides of cabinet shall be at least No. 18 gage sheet iron and double walled with 1 1/2 - inch air space. Joints shall be riveted, welded or made tight by some equally effective means. The door shall be provided with a three-point lock, and the door sill shall be raised at least 2 inches above the bottom of the cabinet. a) On or about 4/5/12 in the Ink Mixing Room; the handle of the storage cabinet marked "Glossy" was able to be turned 360 degrees and did not engaged the three point locking mechanism. No Abatement Certification
Recent events (2)
- — I (S) $2025
- — Z (S) $2700
1910.147 C03 II
- Issued
- Apr 24, 2012
- Abate by
- Jun 8, 2012
- Penalty
- Initial $3,600 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.147(c)(3)(ii): In demonstrating that a level of safety is achieved in the tagout program which is equivalent to the level of safety obtained by using a lockout program, the employer shall demonstrate full compliance with all tagout-related provisions of this standard together with such additional elements as are necessary to provide the equivalent safety available from the use of a lockout device.Additional means to be considered as part of the demonstration of full employee protection shall include the implementation of additional safety measures such as the removal of an isolating circuit element, blocking of a controlling switch, opening of an extra disconnecting device, or the removal of a valve handle to reduce the likelihood of inadvertent energization. a) On or about 4/5/12 in the Sealing department; employees are turning the "On/Off" switch "Off", removing the key, hanging a tag on the power switch and not disconnecting the air prior to set up and change over of Sealing machine #137 without providing any additional safety measures. b) On or about 4/5/12 in the Stamping department; employees are turning the "On/Off" switch off, removing the key, shutting of the hydraulics control power, prior to set up and change over of stamping machine #329 without providing any additional safety measures. Abatement Certification
Recent events (2)
- — I (S) $2700
- — Z (S) $3600
1910.147 C06 I D
- Issued
- Apr 24, 2012
- Abate by
- Jun 8, 2012
- Penalty
- Initial $3,600 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(D): Where tagout is used for energy control, the periodic inspection shall include a review, between the inspector and each authorized and affected employee, of that employee's responsibilities under the energy control procedure being inspected, and the elements set forth in paragraph (c)(7)(ii) of this section. a) On or about 4/5/12 throughout the facility; employer uses a tagout program when changing over the Roll Feeders and Stamping machines however, all of the annual inspections conducted in 2011 (four) were performed on the blade changing in the Bindery department and only with authorized employees using the cutter. Abatement Certification
Recent events (2)
- — I (S) $2700
- — Z (S) $3600
1910.332 B01
- Issued
- Apr 24, 2012
- Abate by
- Jun 8, 2012
- Penalty
- Initial $3,600 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Practices addressed in this standard. Employees shall be trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertain to their respective job assignments. a) On or about 4/18/12 throughout the facility; employees are involved in voltage testing ( 208 volts AC ) and have not been trained on the proper personal protective equipment required for this activity. Abatement Certification
Recent events (2)
- — I (S) $2700
- — Z (S) $3600
1910.335 A01 I
- Issued
- Apr 24, 2012
- Abate by
- Jun 8, 2012
- Penalty
- Initial $3,600 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards shall be provided with,and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed. a) On or about 4/18/12 throughout the facility; employees are involved in using a voltage meter to test for the presence of electricity at 208 volts AC without the use of electrical protective gloves, hard hat, protective clothing and eye protection against the possibility of arc flash hazards. Abatement Certification
Recent events (2)
- — I (S) $2700
- — Z (S) $3600
More inspections in this industry (NAICS 323118)