Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: LINZER PRODUCTS CORP.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LINZER PRODUCTS CORP. in 248 WYANDANCH AVE, WEST BABYLON, NY 11704 (NAICS 424990). OSHA activity number 334037025.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Linzer Products Corp. for free Get an email when a new federal OSHA severe-injury report for Linzer Products Corp. is published. One employer, no account, unsubscribe in one click.
Site address
248 WYANDANCH AVE
City
WEST BABYLON
State
NY
ZIP
11704
Mailing
248 WYANDANCH AVE, WEST BABYLON, NY 11704
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424990
Employees
200
Ownership type
Private (A)

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 3 instances 10 exposed
Issued
Sep 12, 2012
Abate by
Sep 26, 2012
Penalty
Initial $7,000 · Current $4,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) Workplace, Employees were using the Heat Tunnel, Stork Texwrap, Model # T1322-03, Serial #D1232, without a guard on the entrance of the wired conveyor belt.  b) Workplace, Employees were using the Heat Tunnel, Stork Texwrap, Model # T1322-03, Serial #D1232, without a guard on the exit of the wired conveyor belt.  c) Workplace, Employees were using the Heat Tunnel, Stork Texwrap, Model # T1322-03, Serial #D1232, without a guard on in-going nip point, of the exit.    Note:  In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • · I (S) $4000
  • · Z (S) $7000

1910.219 D01

Serious Gravity 5 4 instances 10 exposed
Issued
Sep 12, 2012
Abate by
Sep 26, 2012
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):      a) West side, Sealer Department, L-Sealer Machines #1, #2, #3, #4 off the aisle, did not have pulley guards on an approximately 3" diameter pulleys, driven by 1/2" belts, located approximately 35" off the floor. Employee caught his finger in the in-going nip points, of machine # 2; On or about 04/25/12.    Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • · I (S) $2500
  • · Z (S) $5000

1910.219 E03 I

Serious Gravity 5 4 instances 10 exposed
Issued
Sep 12, 2012
Abate by
Sep 26, 2012
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o)    a) West side, Sealer Department, L-Sealer Machines #1, #2, #3, #4 off the aisle, did not have pulley guards on an approximately 3" diameter pulley, driven by 1/2" belt, located approximately 35" off the flloor. Employee caught his finger in the in-going nip point of machine #2; On or about 04/25/12.    Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • · I (S) $2500
  • · Z (S) $5000