EAST CAMDEN, AR ·
OSHA Inspection: AUSTIN POWDER COMPANY
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of AUSTIN POWDER COMPANY in 7-LC-10 BLANDY ROAD, EAST CAMDEN, AR 71701 (NAICS 325920). OSHA activity number 334324720.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AUSTIN POWDER COMPANY
- Site address
- 7-LC-10 BLANDY ROAD
- City
- EAST CAMDEN
- State
- AR
- ZIP
- 71701
- Mailing
- 7-LC-10 BLANDY ROAD, EAST CAMDEN, AR 71701
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325920
- Employees
- 43
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.132 A
- Issued
- Oct 3, 2012
- Abate by
- Mar 1, 2013
- Penalty
- Initial $5,100 · Current $4,080 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: On or about May 30, 2012 and prior thereto, employees hand dipping molten mix and pouring molten mix were not required to use arm protection for thermal burns, exposing employees to the hazard of burns from spilling or splashing molten mix onto their arms.
Recent events (2)
- · I (S) $4080
- · Z (S) $5100
1910.138 A
- Issued
- Oct 3, 2012
- Abate by
- Oct 11, 2012
- Penalty
- Initial $5,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes: On or about May 30, 2012 and prior thereto, employees hand dipping molten mix and pouring molten mix were not required to gloves that provided thermal protection, exposing employees to the hazard of burns from spilling or splashing molten mix onto their hands.
Recent events (2)
- · I (S) $0
- · Z (S) $5100
1910.212 A01
- Issued
- Oct 3, 2012
- Abate by
- Oct 18, 2012
- Penalty
- Initial $5,100 · Current $4,080 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: At Building 5 in the following instances, kettles were not equipped with guarding to prevent employees pouring and charging kettles from contacting the moving paddle: a. Kettle #1 b. Kettle #2 c. Kettle #3 d. Kettle #4 e. Kettle #5 f. Kettle #6 g. Kettle #7
Recent events (2)
- · I (S) $4080
- · Z (S) $5100
1910.305 G01 I
- Issued
- Oct 3, 2012
- Penalty
- Initial $2,550 · Current $2,040 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(i): Flexible cords and cables were not approved for conditions of use and location: a. On or about May 30, 2012, an orange flexible cord with plug located outside of the scrubber building used to supply power to the sump pumps was not approved for a wet location. This condition exposed employees to the hazard of electrical shock. b.On or about May 30, 2012, an orange flexible cord with plug located outside of the breakroom used to supply power to the freezer box was not approved for a wet location. This condition exposed employees to the hazard of electrical shock.
Recent events (2)
- · I (S) $2040
- · Z (S) $2550
1910.305 G01 IV B
- Issued
- Oct 3, 2012
- Penalty
- Initial $2,550 · Current $2,040 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors: a. On or about May 30, 2012, an orange flexible cord supplying power to the sump pumps was run through a hole in the metal scrubber building. This condition exposed employees to the hazard of electrical shock. b.On or about May 30, 2012, an orange flexible cord supplying power to the freezer box was run through a hole in the window of the breakroom. This condition exposed employees to the hazard of electrical shock.
Recent events (2)
- · I (S) $2040
- · Z (S) $2550
1910.1200 G11
- Issued
- Oct 3, 2012
- Penalty
- Initial $3,000 · Current $2,400 Reduced
22242530
General-duty citation text
29 CFR 1910.1200(g)(11): Safety data sheets were not made readily available, upon request, to designated representatives, the Assistant Secretary, and the Director, in accordance with the requirements of 29 CFR 1910.1020(e): On or about May 15, 2012 and prior thereto, material safety data sheets (MSDS) were not made readily available upon request to designated representatives such as physicians.
Recent events (2)
- · I (S) $2400
- · Z (S) $3000
More inspections at Austin Powder Company
View Austin Powder Company's full OSHA safety record →
More inspections in this industry (NAICS 325920)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334324720.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.