DRESSER, WI —
OSHA Inspection: TENERE INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TENERE INC. in 700 KELLY AVE., DRESSER, WI 54009 (NAICS 332322). OSHA activity number 334645983.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TENERE INC.
- Site address
- 700 KELLY AVE.
- City
- DRESSER
- State
- WI
- ZIP
- 54009
- Mailing
- 700 KELLY AVE., DRESSER, WI 54009
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 280
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 D03
- Issued
- Sep 26, 2012
- Abate by
- Jan 17, 2013
- Penalty
- Initial $7,000 · Current $4,200 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Press Brake Department; The employer did not require Press Brake Set-Up personnel to de-energized and lockout the machinery when they performed set-up operations and procedures.
Recent events (2)
- — I (S) $4200
- — Z (S) $7000
1910.147 D04 I
- Issued
- Sep 26, 2012
- Abate by
- Jan 17, 2013
- Penalty
- Initial $7,000 · Current $4,200 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Press Brake Department; The employer did not require Press Brake Set-Up personnel to use energy isolation lockout devices while performing tool and die changes on the hydraulic press brake machinery.
Recent events (2)
- — I (S) $4200
- — Z (S) $7000
1910.212 A03 II
- Issued
- Sep 26, 2012
- Abate by
- Oct 3, 2012
- Penalty
- Initial $7,000 · Current $4,900 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Press Brake Department; The point of operations on press brake were not guarded to prevent employees from reaching into the tooling during operations.
Recent events (2)
- — I (S) $4900
- — Z (S) $7000
More inspections at Tenere INC.
View Tenere INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334645983.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.