Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DYNAMIC EXTERIORS 10, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DYNAMIC EXTERIORS 10, INC. in 1175-1231 N. GARY, CAROL STREAM, IL 60188 (NAICS 238160). OSHA activity number 334654803.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dynamic Exteriors 10, INC. — free Get an email when a new federal OSHA severe-injury report for Dynamic Exteriors 10, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1175-1231 N. GARY
City
CAROL STREAM
State
IL
ZIP
60188
Mailing
1135 N DRURY LN., ARLINGTON HEIGHTS, IL 60004
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.150 A02

Serious Gravity 1 4 exposed
Issued
Jul 2, 2012
Abate by
Jul 10, 2012
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.150(a)(2):     Access to all available firefighting equipment was not maintained at all times:    On June 12, 2012, employees were exposed to the hazards associated with a fire as they worked with flammable liquids and were not provided with a fire extinguisher.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
  • — Z (S) $1200

1926.501 B10

Serious Gravity 10 3 exposed
Issued
Jul 2, 2012
Abate by
Jul 10, 2012
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(10):     Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and fuardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.    On June 12, 2012, employees were not protected from a fall as they roofed a commercial building with a flat roof, exposing them to a fall hazard of over 25 feet above grade.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 1 4 exposed
Issued
Jul 2, 2012
Abate by
Jul 10, 2012
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.1053(b)(1):     Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:     On June 12, 2012 employees were allowed to use an extension ladder that did not extend three feet past the upper landing, exposing them to a fall hazard of over six feet.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
  • — Z (S) $1200

View Dynamic Exteriors 10, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334654803.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.