Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACE IRRIGATION AND MFG. CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ACE IRRIGATION AND MFG. CO. in 4740 EAST 39TH ST., KEARNEY, NE 68847 (NAICS 332322). OSHA activity number 334700804.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ACE Irrigation and MFG. CO. — free Get an email when a new federal OSHA severe-injury report for ACE Irrigation and MFG. CO. is published. One employer, no account, unsubscribe in one click.
Site address
4740 EAST 39TH ST.
City
KEARNEY
State
NE
ZIP
68847
Mailing
4740 EAST 39TH ST., KEARNEY, NE 68847
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
49
Ownership type
A

5 citations on file for this inspection.

1910.23 E03 V C

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 25, 2012
Abate by
Aug 9, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.23(e)(3)(v)(c):     Protection between the top rail and stair treads, shall be equivalent at least to that afforded by a standard intermediate rail.      At the facility the stairs leading to the Aluminum/PVC fitting storage area the employer is failing to ensure that the stair rail(s) are equipped with an intermediate rail or its equivalent.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.212 A01

Serious Gravity 10 3 instances 5 exposed
Issued
Jul 25, 2012
Abate by
Aug 9, 2012
Penalty
Initial $4,900 · Current $3,430 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, in-running nip point, rotating parts, flying chips and sparks:    At the facility the employer is failing to ensure one or more methods of machine guarding is provided to protect the operator and other employees at the facility from the following hazards including but not limited to:    i.  In the Aluminum Tube area the Ellis Horizontal Band Saw Model 800 Serial 8925603 did not have all unused portions of the band saw blade guarded.      ii.  In the Steel Fabrication area the Johnson Horizontal Band Saw was not equipped with a guard on all unused portion of the blade.    iii. In the Machine shop area the Jet Lathe Model # G4-1440w-1 Serial 830 was not equipped with a point of operation guard.
Recent events (2)
  • — I (S) $3430
  • — Z (S) $4900

1910.212 A05

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 25, 2012
Abate by
Aug 9, 2012
Penalty
Initial $3,500 · Current $2,450 Reduced
29 CFR 1910.212(a)(5):     Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one-half inch:
Recent events (2)
  • — I (S) $2450
  • — Z (S) $3500

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 25, 2012
Abate by
Aug 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1):     Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):       At the facility by the band storage area the employer is failing to ensure that the pulley used to transmit power to the fan was guarded in accordance with this subpart.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 25, 2012
Abate by
Aug 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i):     Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):    At the facility by the band storage area the employer is failing to ensure that the drive belt(s) of the fan were fully enclosed by a guard(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View ACE Irrigation and MFG. CO.'s full OSHA safety record →