Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DURA-BOND PIPE, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DURA-BOND PIPE, LLC in 2176 SOUTH FRONT STREET, STEELTON, PA 17113 (NAICS 332812). OSHA activity number 334714615.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dura-Bond Pipe, LLC — free Get an email when a new federal OSHA severe-injury report for Dura-Bond Pipe, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DURA-BOND PIPE, LLC
Site address
2176 SOUTH FRONT STREET
City
STEELTON
State
PA
ZIP
17113
Mailing
2176 SOUTH FRONT STREET, STEELTON, PA 17113
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
236
Ownership type
A

7 citations on file for this inspection.

1910.36 D02

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 11, 2012
Abate by
Oct 2, 2012
Penalty
Initial $3,960 · Current $2,970 Reduced
29 CFR 1910.36(d)(2):  Fire doors were not maintained in proper operating condition:    (a) Dura-Bond Pipe, LLC, 2716 South Front Street, Steelton, PA - Employees using the outside exit door in the Powder room were exposed to an egress hazard when the door was jammed and in disrepair, on or about June 15, 2012.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2970
  • — Z (S) $3960

1910.37 A03

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 11, 2012
Abate by
Oct 2, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3):  Exits must be free and unobstructed:    (a)  Dura-Bond Pipe, LLC, 2716 South Front Street, Steelton, PA - Employees were exposed to an egress/fire hazard when the exit doors in the Powder room were blocked by equipment and bags of epoxy coating powder, on or about June 15, 2012.    (b)  Dura-Bond Pipe, LLC, 2716 South Front Street, Steelton, PA - Two (2) employees, working in the center of the OD area where pipes move on the line, were exposed to an egress/fire hazard because they had to climb over two (2) sets of I-beams which obstructed their ability to exit the area, on or about June 15, 2012.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 G01 I A

Other-than-serious 1 instance 1 exposed
Issued
Sep 11, 2012
Abate by
Oct 2, 2012
Penalty
Initial $2,700 · Current $2,025 Reduced
29 CFR 1910.134(g)(1)(i)(A):  The employer shall not permit respirators with tight-fitting facepieces to be worn by employees who have any facial hair that comes between the sealing surface of the facepiece and the face or that interferes with valve function:    (a) Dura-Bond Pipe, LLC, 2716 South Front Street, Steelton, PA - An employee working in the Powder room had a full beard while wearing a 3M Model 2091, dual-cartridge, half-mask full-faced respirator exposing the employee to toxic dusts, on or about June 15, 2012.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $2025
  • — Z (S) $2700

1910.305 G01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 11, 2012
Abate by
Oct 2, 2012
Penalty
Initial $2,700 · Current $2,025 Reduced
29 CFR 1910.305(g)(1)(i):  Flexible cords and cables were not approved and suitable for conditions of use and location:    (a) Dura-Bond Pipe, LLC, 2716 South Front Street, Steelton, PA - Employees working in the lab were exposed to a potential shock hazard when temporary wiring was run through two (2) walls, on or about June 16, 2012.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2025
  • — Z (S) $2700

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 11, 2012
Abate by
Oct 2, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    (a) Dura-Bond Pipe, LLC, 2716 South Front Street, Steelton, PA - Employees working in the lab were exposed to a potential shock hazard when extension cords were used as fixed wiring throughout the lab, on or about June 16, 2012.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 P01

Repeat Gravity 1 1 instance 1 exposed
Issued
Sep 11, 2012
Abate by
Oct 2, 2012
Penalty
Initial $5,400 · Current $4,050 Reduced
29 CFR 1910.178(p)(1):  If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition:    (a) Dura-Bond Pipe, LLC, 2716 South Front Street, Steelton, PA - An employee was operating a Pettibone # 2, Super 20 forklift (Model 204 - G/Serial number 5390) and Taylor forklift (Model 650S/Serial number S-W6-30577) which were not properly maintained and had various unsafe conditions, exposing employees to injuries, on or about June 15, 2012.    DURA-BOND COATING, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1910.178(p)(1) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 312636806, CITATION NUMBER 1, ITEM NUMBER 3, AND WAS AFFIRMED AS A FINAL ORDER ON 5/4/10 WITH RESPECT TO A WORKPLACE LOCATED AT MCKEESPORT, PA.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (R) $4050
  • — Z (R) $5400

1910.179 J02 IV

Other-than-serious 1 instance 1 exposed
Issued
Sep 11, 2012
Abate by
Oct 2, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(2)(iv):  Hoist chains, including end connections, were not inspected for excessive wear, twist, distorted links interfering with proper function, or stretch beyond manufacturer's recommendations.  A monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was not available:    (a) Durabond-Pipe, LLC, 2716 South Front Street, Steelton, PA - The chains used to lift equipment on the overhead and gantry cranes did not have a written certification record showing the chains had been inspected for excessive wear, stretch, twist, and distorted links, on or about June 15, 2012.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Dura-Bond Pipe, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334714615.