CINCINNATI, OH —
OSHA Inspection: SEARS HOLDING COMPANY
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SEARS HOLDING COMPANY in 6000 CREEK RD., CINCINNATI, OH 45242 (NAICS 811411). OSHA activity number 334781630.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SEARS HOLDING COMPANY
- Site address
- 6000 CREEK RD.
- City
- CINCINNATI
- State
- OH
- ZIP
- 45242
- Mailing
- 6000 CREEK RD., CINCINNATI, OH 45242
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811411
- Employees
- 70
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.37 A02
- Issued
- Jul 31, 2012
- Abate by
- Aug 29, 2012
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.37(a)(2) Exit routes were not arranged so that employees did not have to travel toward a high hazard area: a) The employer failed to provide an adequate means of egress that would allow employees to evacuate safely during an emergency in which a gasoline fueling storage and dispensing system was maintained 16 feet from the nearest exit route leading to an exit. b) The employer failed to provide an adequate means of egress that would allow employees to evacuate safely during an emergency in which a gasoline fueling storage and dispensing system was maintained 29 feet from the nearest exit.
Recent events (3)
- — F (S) $5000
- — C (S) $7000
- — Z (S) $7000
1910.106 E02 II B 2
- Issued
- Jul 31, 2012
- Abate by
- Aug 29, 2012
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(ii)(b)(2): The quantity of liquid that may be located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building exceeded 120 gallons of Class IB, IC, II, or III liquids in containers: a) On June 20, 2012 the employer stored at least 391 gallons of waste/fresh gasoline and 1000 gallons of waste/fresh oil inside the Garden Repair Center (GRC). b) On June 27, 2012 employer stored 401 gallons of waste gasoline within a Waste Storage Area.
Recent events (3)
- — F (S) $5000
- — C (S) $7000
- — Z (S) $7000
1910.133 A03
- Issued
- Jul 31, 2012
- Abate by
- Aug 20, 2012
- Penalty
- Initial $4,250 · Current $500 Reduced
General-duty citation text
29 CFR 1910.133(a)(3): The employer did not ensure that each affected employee, who wore prescription lenses while engaged in operations that involved eye hazards, used protection that incorporated the prescription in its design, or wore eye protection over the prescription glasses or protective lenses with side shields. a) The employer failed to provide employees with eye protection over prescription glasses to protect against eye hazards caused by flying objects/particles along with chemical splashes while handling gasoline and oil when performing maintenancing on lawnmowers, saws and trimmers within the Garden Repair Center (GRC).
Recent events (3)
- — F (S) $500
- — C (S) $4250
- — Z (S) $4250
1910.307 C02 I
- Issued
- Jul 31, 2012
- Abate by
- Aug 29, 2012
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.307(c)(2)(i): Equipment shall be approved not only for the class of location, but also for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that will be present. Note to paragraph (c)(2)(i) of this section: NFPA 70, the National Electrical Code, lists or defines hazardous gases, vapors, and dusts by "Groups" characterized by their ignitable or combustible properties. a) On or about February of 2012, the electrical outlets/wiring was not approved for the hazardous (classified) location when a fueling storage and dispensing system consisting of a flammable liquid (gasoline) and combustible liquid (oil) was installed.
Recent events (3)
- — F (S) $3500
- — C (S) $7000
- — Z (S) $7000
1910.1200 F06 I
- Issued
- Jul 31, 2012
- Abate by
- Aug 20, 2012
- Penalty
- Initial $2,550 · Current $500 Reduced
General-duty citation text
29 CFR 1910.1200(f)(6)(i): The information specified under paragraphs (f)(1)(i) through (v) of this section for labels on shipped containers; or,
Recent events (3)
- — F (S) $500
- — C (S) $2550
- — Z (S) $2550
1910.1200 F06 II
- Issued
- Jul 31, 2012
- Abate by
- Aug 20, 2012
- Penalty
- Initial $2,550 · Current $500 Reduced
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.
Recent events (3)
- — F (S) $500
- — C (S) $2550
- — Z (S) $2550
More inspections at Sears Holding Company
View Sears Holding Company's full OSHA safety record →
More inspections in this industry (NAICS 811411)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334781630.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.