Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CUDDY ROOFING COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CUDDY ROOFING COMPANY, INC. in 2200 MEMORIAL DRIVE, FARRELL, PA 16121 (NAICS 238160). OSHA activity number 334945789.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cuddy Roofing Company, INC. — free Get an email when a new federal OSHA severe-injury report for Cuddy Roofing Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2200 MEMORIAL DRIVE
City
FARRELL
State
PA
ZIP
16121
Mailing
22 RUTGERS ROAD SUITE 102, PITTSBURGH, PA 15205
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.416 E01

Other-than-serious 1 instance 3 exposed
Issued
Oct 18, 2012
Abate by
Nov 8, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.416(e)(1):     Worn or frayed electric cords or cables were used:    A.)  Cuddy Roofing Company, Inc., 2200 Memorial Road, Farrell, PA  16121, UPMC Horizon-Shenango Valley, on or about June 27, 2012 and times prior thereto:  The extension cord which supplied power to a Milwaukee Sawzall (S/N:  C24A610200031) had damaged strain relief on the male side of the cord exposing the inner insulated wires.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2800

1926.502 F01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 18, 2012
Abate by
Nov 8, 2012
Penalty
Initial $3,500 · Current $2,500 Reduced
29 CFR 1926.502(f)(1)(i):     When no mechanical equipment was being used the warning line was not erected at least 6 feet (1.8m) from the roof edge:    A.)  Cuddy Roofing Company, Inc., 2200 Memorial Road, Farrell, PA  16121, UPMC Horizon-Shenango Valley, on or about June 27, 2012 and times prior thereto:  Employees performing roofing work on a flat roof 25 feet from the ground.  A warning line system was 38 inches from the edge of the roof on the west side of the structure.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3500

1926.502 F01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Oct 18, 2012
Abate by
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(1):     Warning lines were not erected around all sides of the roof work area:    A.)  Cuddy Roofing Company, Inc., 2200 Memorial Road, Farrell, PA  16121, UPMC Horizon-Shenango Valley, on or about June 27, 2012 and times prior thereto:  On the south side of the roof, there were gaps of at least 34-inches between the wall and the last warning line stansion.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 F02 II

Other-than-serious 1 instance 3 exposed
Issued
Oct 18, 2012
Abate by
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(2)(ii):     The rope, wire, or chain was not rigged or supported in such a way that its lowest point (including sag) was not less than 34 inches (0.9 m) from the walking/working surface and its highest point no more than 39 inches (1.0 m) from the walking/working surface.    A.)  Cuddy Roofing Company, Inc., 2200 Memorial Road, Farrell, PA  16121, UPMC Horizon-Shenango Valley, west side of the roof, on or about June 27, 2012 and times prior thereto:   Employees performing roofing work 25 feet above ground level were supplied with a warning line system thats lowest point was 24 inches from the roof surface.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.502 F01 III

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 18, 2012
Abate by
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(1)(iii):     Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines:    A.)  Cuddy Roofing Company, Inc., 2200 Memorial Road, Farrell, PA  16121, UPMC Horizon-Shenango Valley, west side of the roof, on or about June 27, 2012 and times prior thereto:   Employees performing roofing work 25 feet above the ground level on a flat roof were accessing the roof of the structure via an extension ladder.  An access path was not erected from the ladder to the warning line system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.28 A

Other-than-serious 1 instance 1 exposed
Issued
Oct 18, 2012
Abate by
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.28(a):     The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions.    A.)  Cuddy Roofing Company, Inc., 2200 Memorial Road, Farrell, PA  16121, UPMC Horizon-Shenango Valley, on or about June 27, 2012 and times prior thereto:  An employee operating a Milwaukee SawZall to cut up fiberboard during the removal of old roofing products was wearing eye wear that did not bear the logo of ANSI 87.1.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Cuddy Roofing Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334945789.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.