WARWICK, RI —
OSHA Inspection: KENNEY MANUFACTURING COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KENNEY MANUFACTURING COMPANY in 1000 JEFFERSON BLVD., WARWICK, RI 02886 (NAICS 337920). OSHA activity number 334979382.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KENNEY MANUFACTURING COMPANY
- Site address
- 1000 JEFFERSON BLVD.
- City
- WARWICK
- State
- RI
- ZIP
- 02886
- Mailing
- 1000 JEFFERSON BLVD., WARWICK, RI 02886
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337920
- Employees
- 370
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.303 B02
- Issued
- Aug 15, 2012
- Penalty
- Initial $3,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. Shipping Department: The electric power strips powering the Robopac Stretch Film Machines, and other portable equipment, were used in lieu of permanent wiring. b. Shipping Department: The electric power strip powering the Robopac Strapping Machine, and other portable equipment, was used in lieu of permanent wiring.
Recent events (2)
- — I (S) $1500
- — Z (S) $3000
1910.303 F02
- Issued
- Aug 15, 2012
- Penalty
- Initial $2,250 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a. Shipping Department, Panel # P25: The electric panel was not appropriately labeled to indicate the purpose of each breaker.
Recent events (2)
- — I (S) $0
- — Z (S) $2250
1910.303 G01 II
- Issued
- Aug 15, 2012
- Penalty
- Initial $3,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a. Janitor Storage Area: The area in front of and behind the main electical panel was used for storage of boxes, janitorial equipment, a door and other items.
Recent events (2)
- — I (S) $0
- — Z (S) $3000
More inspections at Kenney Manufacturing Company
View Kenney Manufacturing Company's full OSHA safety record →
More inspections in this industry (NAICS 337920)
More inspections in RI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334979382.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.