Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: UNISTRESS CORP.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of UNISTRESS CORP. in WOODLAWN PARKING GARAGE, SARATOGA SPRINGS, NY 12866 (NAICS 327390). OSHA activity number 335004586.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Unistress Corp. for free Get an email when a new federal OSHA severe-injury report for Unistress Corp. is published. One employer, no account, unsubscribe in one click.
Establishment
UNISTRESS CORP.
Site address
WOODLAWN PARKING GARAGE
City
SARATOGA SPRINGS
State
NY
ZIP
12866
Mailing
P.O. BOX 1145, PITTSFIELD, MA 01202
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
180
Ownership type
Private (A)

2 citations on file for this inspection.

1926.21 B02

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Oct 24, 2012
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1926.21(b)(2):     The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    (a) First Story Floor, prior to removal of temporary support bracing- the employer did not adequately instruct the subcontractor employees in the safe removal of brace rods, including but not limited to the location or identification of brace rods which should not be removed.
Recent events (2)
  • · I (S) $0
  • · Z (S) $7000

1926.704 A

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Oct 24, 2012
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1926.704(a):     Precast concrete wall units, structural framing and tilt-up wall panels were not adequately supported to prevent overturning and to prevent collapse until permanent connections were completed:    (a) First Story Floor, between Column Lines 4 & 5, A & B, on or about June 21, 2012 - the upper concrete spandrel panel was not properly supported in that: permanent connections were not completed prior to removal of support bracing.
Recent events (2)
  • · I (S) $0
  • · Z (S) $7000

View Unistress Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335004586.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.