Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PEAK OILFIELD SERVICES

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of PEAK OILFIELD SERVICES in STEELHEAD PLATFORM, NIKISKI, AK 99635 (NAICS 811310). OSHA activity number 335225199.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Peak Oilfield Services — free Get an email when a new federal OSHA severe-injury report for Peak Oilfield Services is published. One employer, no account, unsubscribe in one click.
Site address
STEELHEAD PLATFORM
City
NIKISKI
State
AK
ZIP
99635
Mailing
2525 C STREET, STE 201, ANCHORAGE, AK 99503
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
5
Ownership type
A

4 citations on file for this inspection.

1910.254 D09 III

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 7, 2012
Penalty
Initial $2,250 · Current $1,125 Reduced
29 CFR 1910.254(d)(9)(iii):     Cables with damaged insulation or exposed bare conductors were not replaced:    Dry Sack room:  On or about July 12, 2012 and times prior thereto, the welding stinger was cut to the conductor at 24 inches from the holder.  This exposed employees to electric shock hazards from coming in contact with the conductor during welding operations.
Recent events (2)
  • — I (S) $1125
  • — Z (S) $2250

1910.37 A04

Other-than-serious 1 instance 5 exposed
Issued
Sep 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(4):     Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:      2nd floor living area:  On or about July 12, 2012 and times prior thereto, both exit signs lights for both exit access areas were not working.  This exposed employees to smoke inhalation hazards from delays in exiting the area.    Dry Sack Room:  On or about 12 July 2012 and times prior thereto, the emergency lighting in the Dry Sack Room was inoperable.  This exposed employees to smoke inhalation and/or fire hazards from delays in exiting the building.
Recent events (1)
  • — Z (O) $0

1910.242 A

Other-than-serious 1 instance 3 exposed
Issued
Sep 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.242(a):     Hand and portable powered tools or equipment were not kept in safe condition:    Dry Sack room:  On or about July 12, 2012 and times prior thereto, the Dewalt chop saw S/N 347579 had a damaged cord.  This exposed employees to electric shock hazards.
Recent events (1)
  • — Z (O) $0

1910.334 A03 II

Other-than-serious 1 instance 3 exposed
Issued
Sep 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(3)(ii):     Attachment plugs and receptacles were connected or altered in a manner which prevented proper continuity of the electric equipment grounding conductor at the point where plugs were attached to receptacles:      Dry Sack room:  On or about July 12, 2012 and times prior thereto, an extension cord used for powering other equipment had no ground pin.  This exposed employees to electrical shock hazards.
Recent events (1)
  • — Z (O) $0

View Peak Oilfield Services's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335225199.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.