OSHA Inspection: ILSCO EXTRUSIONS INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of ILSCO EXTRUSIONS INC. in 93 WERNER ROAD, BUILDING A, GREENVILLE, PA 16125 (NAICS 331318). OSHA activity number 335286985.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ilsco Extrusions INC. — free Get an email when a new federal OSHA severe-injury report for Ilsco Extrusions INC. is published. One employer, no account, unsubscribe in one click.
Site address
93 WERNER ROAD, BUILDING A
City
GREENVILLE
State
PA
ZIP
16125
Mailing
93 WERNER ROAD, BUILDING A, GREENVILLE, PA 16125
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331318
Employees
25
Ownership type
A

2 citations on file for this inspection.

1910.95 G06

Serious Gravity 5 1 instance 19 exposed
Issued
Oct 2, 2012
Abate by
Nov 15, 2012
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.95(g)(6):  At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels :    a.) ILSCO Extrusions, Inc., 93 Werner Road Building A, Greenville, PA 16125, on or about July 16, 2012, Quest Technology NoisePro dosimeters were placed on the Extrusion Press Operator, Dye Repairman, and the Extrusion Specialist (Finish Saw area) for totals of 463, 466, and 465 minutes, respectively.  The equivalent 8-hr dose and Time Weighted Average (TWA) for the Extrusion Press Operator was 175.8% and 94.3 dB.  The equivalent 8-hr dose and Time Weighted Average (TWA) for the Dye Repairman was 117% and 91.3 dB.  The equivalent 8-hr dose and Time Weighted Average (TWA) for the Extrusion Specialist was 61.1 % and 86.6 dB.  Company employees had not been provided with annual audiograms in 2011, and 2012.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.151 C

Other-than-serious 1 instance 4 exposed
Issued
Oct 2, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a.) ILSCO Extrusions, Inc., (Dye shop-water bath area) 93 Werner Road Building A, Greenville, PA 16125, on or about July 16, 2012, and times prior thereto:  Company employees work with and around corrosive chemicals including, but not limited to, Sodium Hydroxide.  While a plumbed emergency eyewash and shower was available in an area adjacent to the water bath area, the unit was not maintained in compliance with ANSI Z358.1-1998 for Emergency Eyewash and Shower Equipment in that:  	  1. Weekly inspections of the equipment were not conducted. The emergency eyewash unit was not activated weekly to verify proper operation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Ilsco Extrusions INC.'s full OSHA safety record →