Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: FOREST SERVICE - LASSEN NATIONAL FOREST

Programmed Related inspection · Health discipline

On , OSHA opened a programmed Related health inspection of FOREST SERVICE - LASSEN NATIONAL FOREST in EAGLE LAKE RANGER DISTRICT OFFICE 477-050 EAGLE LAKE ROAD, SUSANVILLE, CA 96130 (NAICS 924120). OSHA activity number 335420386.

Watch Forest Service - Lassen National Forest — free Get an email when a new federal OSHA severe-injury report for Forest Service - Lassen National Forest is published. One employer, no account, unsubscribe in one click.
Site address
EAGLE LAKE RANGER DISTRICT OFFICE 477-050 EAGLE LAKE ROAD
City
SUSANVILLE
State
CA
ZIP
96130
Mailing
2550 RIVERSIDE DRIVE, SUSANVILLE, CA 96130
Inspection type
Programmed Related (J)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
120
Ownership type
D

4 citations on file for this inspection.

1910.22 D01

Serious Gravity 10 2 instances 92 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked on plates of approved design which were supplied and securely affixed by the owner of the building, or the duly authorized agent, in a conspicuous place in each space to which they related:      a)  U.S. Forest Service Lassen National Forest Eagle Lake Ranger District - Warehouse - On or about June 28, 2012 and at times prior thereto, the Timber mezzanine used for storage including, but not limited to, lockers, work surfaces with storage underneath and a wood enclosure containing additional lockers and supplies for Timber staff activities was not marked with the approved load rating nor was the load rating for the mezzanine known to ensure it was not a hazard for employees while on the mezzanine and accessing the area underneath the mezzanine.     b)  U.S. Forest Service Lassen National Forest Eagle Lake Ranger District - Warehouse - On or about June 28, 2012 and at times prior thereto, the Fire mezzanine used by Fire, Range, Archeology and Admin for storage including, but not limited to, lockers, wood storage cages with stored supplies and a file cabinet was not marked with the approved load rating nor was the load rating for the mezzanine known to ensure it was not a hazard for employees accessign the mezzanine or in the storage spaces underneath the mezzanine.
Recent events (1)
  • — Z (S) $0

1910.37 B02

Serious Gravity 10 1 instance 92 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":      a)  U.S. Forest Service Lassen National Forest Eagle Lake Ranger District - Warehouse - On or about June 27, 2012 and at times prior thereto, an exit sign was not posted on/at the designated exit door for the Eagle Lake Ranger District Warehouse to ensure employees were able to locate the exit in an emergency.  The warehouse has no windows and other openings, doors and areas could be mistaken for the exit if it does not have an exit sign.  An exit sign should be clearly visible from all areas of the warehouse.
Recent events (1)
  • — Z (S) $0

1910.37 B04

Serious Gravity 5 1 instance 100 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:      a)  b)  U.S. Forest Service Lassen National Forest Eagle Lake Ranger District - District Office - On or about June 28, 2012 and at times prior thereto, sign(s) indicating the path to the nearest designated exit route were not posted at the "T" of the hallway containing offices and the entrance/reception are of the District Office indicating the direction to the nearest exit at either the entrance or the far end of the hallway.  An exit sign at the end of the hallway was not readily visible from any area of the hallway, until at the exit door, as it was attached at ceiling height.  Hallway doors are glass panelled and light can be seen through them during the day.
Recent events (1)
  • — Z (S) $0

1910.303 G01

Serious Gravity 10 1 instance 92 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment:      a)  a)  U.S. Forest Service Lassen National Forest Eagle Lake Ranger District - Warehouse - On or about June 28, 2012 and at times prior thereto, the warehouse did not have the required 3.0 foot depth of clearance in front of the electrical disconnect.  A frezzer was located in front of the disconnect resulting in difficult access and an inability to maintain the equipment.
Recent events (1)
  • — Z (S) $0

View FOREST SERVICE - LASSEN NATIONAL FOREST's full OSHA safety record →