ALLENTOWN, PA ·
OSHA Inspection: WIN-HOLT EQUIPMENT GROUP
Follow-up inspection · Health discipline
At a glance
On , OSHA opened a follow-up health inspection of WIN-HOLT EQUIPMENT GROUP in 7028 SNOWDRIFT ROAD SUITE 100, ALLENTOWN, PA 18106 (NAICS 332999). OSHA activity number 335486189.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WIN-HOLT EQUIPMENT GROUP
- Site address
- 7028 SNOWDRIFT ROAD SUITE 100
- City
- ALLENTOWN
- State
- PA
- ZIP
- 18106
- Mailing
- 7028 SNOWDRIFT ROAD SUITE 100, ALLENTOWN, PA 18106
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 40
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.252 A01 I
- Issued
- Sep 19, 2012
- Abate by
- Sep 26, 2012
- Penalty
- Initial $2,295 · Current $1,607 Reduced
General-duty citation text
29 CFR 1910.252(a)(1)(i): When the object to be welded or cut could not be readily moved, all movable fire hazards in the vicinity were not taken to a safe place: a) Welding Area: Employees, Welders, were exposed to fire hazards when welding galvanized steel, stainless steel, and aluminum in welding booths with cardboard sheets hanging on the booth curtain to block the welding flash from the other booths, on or about 08/08/2012. b) Welding Area: Employees, Welders, were exposed to fire hazards when welding galvanized steel in a welding booth that had a stack of empty cardboard boxes in the booth, on or about 08/08/2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $1606.5
- · Z (S) $2295
1910.1000 B01
- Issued
- Sep 19, 2012
- Abate by
- Dec 18, 2012
- Penalty
- Initial $4,590 · Current $3,213 Reduced
2610
General-duty citation text
29 CFR 1910.1000(b)(1): Employee(s) were exposed to an airborne concentration of zinc oxide listed in Table Z-2 in excess of the 8 hour Time Weighted Average concentration of 5 milligram per cubic meter of air: a) Welding Area: An employee, Welder, while welding galvanized steel cart corral bases was exposed to zinc oxide at an 8 hour time-weighted average (TWA) of 6.47 milligrams per cubic meter of air. This level is 1.29 times the permissible exposure limit of 5 milligrams per cubic meter of air. This exposure occurred over a 437 minute sampling period on 08/08/2012. A zero exposure is assumed for the 43 minutes not sampled. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.
Recent events (2)
- · I (S) $3213
- · Z (S) $4590
1910.1000 E
- Issued
- Sep 19, 2012
- Abate by
- Dec 18, 2012
- Penalty
- Initial $0 · Current $0
2610
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): a) Welding Area: An employee, Welder, while welding galvanized steel cart corral bases was exposed to zinc oxide at an 8 hour time-weighted average (TWA) of 6.47 milligrams per cubic meter of air. This level is 1.29 times the permissible exposure limit of 5 milligrams per cubic meter of air. This exposure occurred over a 437 minute sampling period on 08/08/2012. A zero exposure is assumed for the 43 minutes not sampled. Effective engineering or administrative controls were not utilized to reduce the welders zinc oxide exposures below the permissible exposure limit, on or about 08/08/2012. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records. Feasible abatement methods include but are not limited to: 1) Provide localized exhaust ventilation to capture metal fumes at the point of generation and exhaust them outside the work environment. 2) Use administrative controls such as limiting employee exposure to welding fume by limiting the amount of time employees would weld in a day. This cound be accomplished by rotating employee to a job where there would not be exposure to welding fumes. ABATEMENT STEPS ARE AS FOLLOW: STEP 1 As an interim measure, effective respiratory protection shall be provided to and used by exposed employees until feasible and/or administrative controls can be implemented or whenever such controls fail to reduce employee exposure to within permissible exposure limits. STEP 2 - A written detailed plan of abatement shall be submitted to the Area Director outlining a schedule for the implementation of engineering and/or administrative measures to control employee exposures to hazardous substances as referenced in this citation. This plan shall include, at a minimum, target dates for the following actions which must be consistent with the dates required by this citation: 1. Evaluation of engineering control options; 2. Selection of optimum control method and completion of design; 3. Procurement, installation and operation of selected control measures; 4. Testing and acceptance or modification/redesign of controls. All proposed control measures shall be evaluated for each particular use by a competent industrial hygienist or other technically qualified person. STEP 3 - Abatement shall have been completed by the implementation of feasible engineering and/or administrative controls upon verification of their effectiveness in achieving compliance.
Recent events (1)
- · Z (S) $0
1910.134 A01
- Issued
- Sep 19, 2012
- Abate by
- Sep 26, 2012
- Penalty
- Initial $0 · Current $0
2610
General-duty citation text
29 CFR 1910.134(a)(1): When effective engineering controls were not feasible or while they were being instituted, appropriate respirators were not used pursuant to the requirements of 29 CFR 1910.134: a) Welding Area: An employee, Welder, while welding galvanized steel cart corral bases was exposed to zinc oxide at an 8 hour time-weighted average (TWA) of 6.47 milligrams per cubic meter of air. This level is 1.29 times the permissible exposure limit of 5 milligrams per cubic meter of air. The employer did not establish and implement a written respiratory protection program with worksite-specific procedures for employees who were exposed to zinc oxide above the permissible exposure limit, on or about 08/08/2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (1)
- · Z (S) $0
1910.134 A02
- Issued
- Sep 19, 2012
- Abate by
- Oct 19, 2012
- Penalty
- Initial $0 · Current $0
2610
General-duty citation text
29 CFR 1910.134(a)(2): The employer did not establish and maintain a respiratory protection program which included the requirements outlined in 29 CFR 1910.134(c): a) Welding Area: An employee, Welder, while welding galvanized steel cart corral bases was exposed to zinc oxide at an 8 hour time-weighted average (TWA) of 6.47 milligrams per cubic meter of air. This level is 1.29 times the permissible exposure limit of 5 milligrams per cubic meter of air. The employer did not establish and implement a written respiratory protection program with worksite-specific procedures for employees who were exposed to zinc oxide above the permissible exposure limit, on or about 08/08/2012. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (1)
- · Z (S) $0
1910.252 C06 II
- Issued
- Sep 19, 2012
- Abate by
- Dec 18, 2012
- Penalty
- Initial $0 · Current $0
2610
General-duty citation text
29 CFR 1910.252(c)(6)(ii): Indoors, welding or cutting involving zinc-bearing base or filler metals coated with zinc-bearing materials was not done in accordance with 29 CFR 1910.252(c)(3): a) Welding Area: An employee, Welder, while welding galvanized steel cart corral bases was exposed to zinc oxide at an 8 hour time-weighted average (TWA) of 6.47 milligrams per cubic meter of air. This level is 1.29 times the permissible exposure limit of 5 milligrams per cubic meter of air. This exposure occurred over a 437 minute sampling period on 08/08/2012. A zero exposure is assumed for the 43 minutes not sampled. As required by 1910.252(c)(3) local exhaust hoods or booths were not utilized when employees were welding on metals containing a zinc coating, on or about 08/08/2012. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.
Recent events (1)
- · Z (S) $0
More inspections at Win-Holt Equipment Group