Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JIAN HUA CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JIAN HUA CONSTRUCTION, INC. in LOT 2323 2-2NEW 4 NEAR DYA, MANGILAO, GU 96923 (NAICS 236115). OSHA activity number 335489043.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jian HUA Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Jian HUA Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
LOT 2323 2-2NEW 4 NEAR DYA
City
MANGILAO
State
GU
ZIP
96923
Mailing
PO BOX 20399, BARRIGADA, GU 96921
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.95 A

Serious Gravity 1 2 instances 2 exposed
Issued
Jan 4, 2013
Abate by
Jan 16, 2013
Penalty
Initial $1,200 · Current $900 Reduced
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, and maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact:    (a) Construction Site: On or about July 31, 2012, and at times prior thereto, employees were exposed to dermal hazards while mixing various mortars containing portland cement without wearing a shirt. The employer did not ensure adequate personal protective equipment was available and used.      (b) Construction Site: On or about July 31, 2012, and at times prior thereto, employees were exposed to dermal hazards while mixing various mortars containing portland cement without rubber gloves. The employer did not ensure adequate personal protective equipment was available and used.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1926.102 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 4, 2013
Abate by
Jan 16, 2013
Penalty
Initial $1,200 · Current $900 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:     (a) Construction Site: On or about July 31, 2012, and at times prior thereto, employees were exposed to eye injuries while cutting tile without safety glasses or equivalent eye protection. The employer did not ensure adequate personal protective equipment was provided and used.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1926.403 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2013
Abate by
Jan 16, 2013
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:     (a) Construction Site: On or about July 31, 2012, and at times prior thereto, employees were exposed to electrical shock hazards while using a Power Source relocateable power tap to provide power to tools such as, but not limited to, a Makita 4 inch grinder.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1926.404 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2013
Abate by
Jan 16, 2013
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:    (a) Construction Site: On or about July 31, 2012, and at times prior thereto, employees were exposed to electrical shock hazards while using a receptacle outlet, without a GFCI, which provided power to tools such as, but not limited to, a Ridgid drill / mixer to mix mortar.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1926.405 G02 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2013
Abate by
Jan 16, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:    (a) Construction Site: On or about July 31, 2012, and at times prior thereto, employees used a flexible cord without strain relief to provide power to the receptacle outlet used for mixing mortar. This condition exposes employees to electrical shock hazards while using such equipment.