CHICAGO, IL —
OSHA Inspection: FRANCISCO RAMIREZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FRANCISCO RAMIREZ in 5007 N. KILDARE AVE., CHICAGO, IL 60630 (NAICS 238160). OSHA activity number 335509790.
Where did this inspection happen?
- Establishment
- FRANCISCO RAMIREZ
- Site address
- 5007 N. KILDARE AVE.
- City
- CHICAGO
- State
- IL
- ZIP
- 60630
- Mailing
- 1840 N. GOODWIN APT. 32B, PALATINE, IL 60074
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1903.19 C01
- Issued
- Dec 6, 2012
- Abate by
- Jan 25, 2013
- Penalty
- Initial $400 · Current $400
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: Francisco Ramirez dba Francisco Ramirez failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected: Citation Number Item Number Abatement Date 01 01 9/12/2012 01 02 10/03/2012 01 03 9/12/2012 In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (O) $400
1926.501 B13
- Issued
- Sep 5, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Employees performing roofing work were exposed to fall hazards of approximately 13 feet. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $2800
1926.503 A01
- Issued
- Sep 5, 2012
- Abate by
- Oct 3, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Employees exposed to fall hazards were not provided the training needed to recognize and correct those hazards. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (S) $2000
1926.1053 B01
- Issued
- Sep 5, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a) Employees were using an extension ladder which did not extend 3 feet above the upper landing being accessed. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (S) $1600
More inspections at Francisco Ramirez
View Francisco Ramirez's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335509790.