Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RIVER CITY MASONRY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RIVER CITY MASONRY, INC. in 1910 MAIN STREET, MADISON, MS 39110 (NAICS 238140). OSHA activity number 335618781.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch River City Masonry, INC. — free Get an email when a new federal OSHA severe-injury report for River City Masonry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1910 MAIN STREET
City
MADISON
State
MS
ZIP
39110
Mailing
1007 COLLINGHAM COVE, COLLIERVILLE, TN 38017
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 20, 2012
Abate by
Sep 4, 2012
Penalty
Initial $1,360 · Current $816 Reduced
29 CFR 1926.451(b)(1)(i):     Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary.    a) 1910 Main St in Madison, MS - On or about August 8, 2012, employees were installing a brick line on a building while standing on a scaffold platform that had a total gap between the platform and the uprights of 11 inches.
Recent events (2)
  • — I (S) $816
  • — Z (S) $1360

1926.451 B05 I

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 20, 2012
Abate by
Sep 4, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(5)(i):     The end of a platform 10 feet or less in length extended over its support more than 12 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilivered end.    a) 1910 Main St in Madison, MS - On or about August 8, 2012, employees were installing a brick line on a building while standing on a cantilevered scaffold platform that extended 18 inches past the support.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E06

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 20, 2012
Abate by
Sep 4, 2012
Penalty
Initial $1,360 · Current $816 Reduced
29 CFR 1926.451(e)(6):     Integral prefabricated scaffold access frames did not meet the requirements of paragraphs (e)(6)(i)-(vi) of this section:    a) 1910 Main St in Madison, MS - On or about August 8, 2012, employees were accessing a scaffold platform by climbing on the end frame that was not designed to be an access ladder.
Recent events (2)
  • — I (S) $816
  • — Z (S) $1360

1926.451 E08

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 20, 2012
Abate by
Sep 11, 2012
Penalty
Initial $2,040 · Current $1,224 Reduced
29 CFR 1926.451(e)(8):     Direct access to or from another surface was used when the scaffold was more than 14 inches (36 cm) horizontally and/or 24 inches (61 cm) vertically from the other surface:    a) 1910 Main St in Madison, MS - On or about August 8, 2012, an employee was standing over a 19 inch gap from the platform surface of the North scaffold to the platform surface of the South scaffold. The distance from the North platform to the building surface was 33.5 inches and the distance from the South platform to the building was 40 inches on one end and 36 inches on the other end.
Recent events (2)
  • — I (S) $1224
  • — Z (S) $2040

View River City Masonry, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335618781.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.