SOUTH CHARLESTON, OH ·
OSHA Inspection: YAMADA NORTH AMERICA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of YAMADA NORTH AMERICA, INC. in 9000 COLUMBUS CINCINNATI ROAD, SOUTH CHARLESTON, OH 45368 (NAICS 336399). OSHA activity number 335680385.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- YAMADA NORTH AMERICA, INC.
- Site address
- 9000 COLUMBUS CINCINNATI ROAD
- City
- SOUTH CHARLESTON
- State
- OH
- ZIP
- 45368
- Mailing
- 9000 COLUMBUS CINCINNATI ROAD, SOUTH CHARLESTON, OH 45368
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336399
- Employees
- 450
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.147 D03
- Issued
- Sep 4, 2012
- Abate by
- Oct 9, 2012
- Penalty
- Initial $4,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). a) The electrical disconnect on the UBE die cast machine in the presss department was not actuated to disable power while trouble shooting the ladle.
Recent events (2)
- · I (S) $2000
- · Z (S) $4000
1910.147 D04 I
- Issued
- Sep 4, 2012
- Abate by
- Oct 9, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees. a) A lockout device(s) were not attached to the energy isolation point on the UBE die cast machine in the press department during the trouble shooting of the ladle.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 B01 II
- Issued
- Sep 4, 2012
- Penalty
- Initial $2,550 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. a) Knockouts in the eiectical junction box for the outlets were not covered.
Recent events (2)
- · I (S) $1200
- · Z (S) $2550
1910.305 G02 III
- Issued
- Sep 4, 2012
- Penalty
- Initial $2,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. a) Flexible cord attached to the Robot Teach pedant was not equipped with strain relief to prevent movement or damage to conductors.
Recent events (2)
- · I (S) $0
- · Z (S) $2550
More inspections at Yamada North America, INC.
View Yamada North America, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336399)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335680385.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.