SOUTH CHARLESTON, OH —
OSHA Inspection: YAMADA NORTH AMERICA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of YAMADA NORTH AMERICA, INC. in 9000 COLUMBUS CINCINNATI ROAD, SOUTH CHARLESTON, OH 45368 (NAICS 336350). OSHA activity number 347145617.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- YAMADA NORTH AMERICA, INC.
- Site address
- 9000 COLUMBUS CINCINNATI ROAD
- City
- SOUTH CHARLESTON
- State
- OH
- ZIP
- 45368
- Mailing
- 9000 COLUMBUS CINCINNATI RD, SOUTH CHARLESTON, OH 45368
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336350
- Employees
- 480
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- May 8, 2024
- Abate by
- Jun 4, 2024
- Penalty
- Initial $11,524 · Current $8,067 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i):Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance. a) On or about December 6, 2023 the employer did not develop, document, and utilize an energy control procedure for the Buehler saw in that an energy isolation procedure was not developed for employees to use while changing 14" blades exposing them to rotating parts. b) On or about December 6, 2023 the employer did not develop, document, and utilize an energy control procedure for the Leco saw in that an energy isolation procedure was not developed for employees to use while changing 14" blades exposing them to rotating parts.
Recent events (2)
- — I (S) $8066.8
- — Z (S) $11524
1910.147 C07 I
- Issued
- May 8, 2024
- Abate by
- Jun 4, 2024
- Penalty
- Initial $12,676 · Current $8,873 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i):The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: 1910.147(c)(7)(i)(A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. a) On or about December 6, 2023 the employer did not provide authorized employee lockout tagout training prior to employees changing blades on the Buehler and Leco saws in that employees did not know the methods and means necessary for energy isolation and control.
Recent events (2)
- — I (S) $8873.2
- — Z (S) $12676
1910.147 D
- Issued
- May 8, 2024
- Abate by
- Jun 4, 2024
- Penalty
- Initial $11,524 · Current $8,067 Reduced
General-duty citation text
29 CFR 1910.147(d):Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: (d)(1) Preparation for shutdown. Before an authorized or affected employee turns off a machine or equipment, the authorized employee shall have knowledge of the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy.? ? (d)(2) Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage.? ? (d)(3) Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).? ? (d)(4) Lockout or tagout device application.? ? (d)(4)(i) Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.? ? (d)(4)(ii) Lockout devices, where used, shall be affixed in a manner to that will hold the energy isolating devices in a "safe" or "off" position.? ? (d)(5) Stored energy.? ? (d)(5)(i) Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy shall be relieved, disconnected, restrained, and otherwise rendered safe.? ? (d)(5)(ii) If there is a possibility of reaccumulation of stored energy to a hazardous level, verification of isolation shall be continued until the servicing or maintenance is completed, or until the possibility of such accumulation no longer exists.? ? (d)(6) Verification of isolation. Prior to starting work on machines or equipment that have been locked out or tagged out, the authorized employee shall verify that isolation and deenergization of the machine or equipment have been accomplished.? a) On or about December 6, 2023, employees were exposed to machine hazards associated with moving parts during blade changes of the Buehler and Leco saws. The employer did not ensure employees implemented energy control application steps (d)(1) through (d)(6) prior to conducting servicing and maintenance on the saws.
Recent events (2)
- — I (S) $8066.8
- — Z (S) $11524
More inspections at Yamada North America, INC.
View Yamada North America, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336350)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347145617.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.