GREELEY, CO —
OSHA Inspection: RAFAEL RAMOS ROOFING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RAFAEL RAMOS ROOFING in 7304 WEST 21ST. STREET, GREELEY, CO 80634 (NAICS 238160). OSHA activity number 335714788.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAFAEL RAMOS ROOFING
- Site address
- 7304 WEST 21ST. STREET
- City
- GREELEY
- State
- CO
- ZIP
- 80634
- Mailing
- 602 28TH AVENUE, GREELEY, CO 80634
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.501 B13
- Issued
- Dec 7, 2012
- Penalty
- Initial $2,400 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): " Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, personal fall arrest system or other approved alternative fall protection system: (a) Rafael Ramos Roofing, 7304 West 21st Street, Greeley, CO 80634: On or about August 13, 2012, the employer had not ensured the use of fall protection while employees replaced shingles on a 5/12 pitch roof. Condition exposed employees to a fall hazard of approximately 8 feet. Rafael Ramos was previously cited for a violation of this Occupational Safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13) contained in OSHA inspection number 313720443, citation number 1, item number 1, issued on July 21st, 2010, with respect to a workplace located at 4855 Spokane Way, Colorado Springs, CO 80631. Abatement Note: Abatement certification is not required for this item. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.
Recent events (2)
- — I (R) $1200
- — Z (R) $2400
More inspections at Rafael Ramos Roofing