Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PEACH STATE ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PEACH STATE ROOFING, INC. in 1700 MEDICAL WAY, SNELLVILLE, GA 30078 (NAICS 238160). OSHA activity number 335761581.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Peach State Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for Peach State Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1700 MEDICAL WAY
City
SNELLVILLE
State
GA
ZIP
30078
Mailing
1655-A SPECTRUM DRIVE, LAWRENCEVILLE, GA 30043
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.502 D15

Other-than-serious 1 instance 2 exposed
Issued
Aug 29, 2012
Abate by
Sep 20, 2012
Penalty
Initial $4,950 · Current $6,930
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person.    On or about 8/2/2012, at the Emory Eastside hospital job site, employees were exposed to fall hazards of 15'5" to the roof side and 57'8" to the outside as they stood on a parapet wall using fall protection that was anchored off by wrapping the rope used in the system around a steel beam and back into the rope itself.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $6930
  • — Z (S) $4950

1926.502 D16 III

Other-than-serious 1 instance 2 exposed
Issued
Aug 29, 2012
Abate by
Sep 20, 2012
Penalty
Initial $6,930 · Current $0 Reduced
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level.    On or about 8/2/2012, at the Emory Eastside Hospital job site, employees were standing on an outside parapit roof wall -  exposed to fall hazards of 15'5" to the roof side as employees were (improperly) anchored off at the roof level 15'5" below where they were standing on the parapet wall.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $0
  • — Z (S) $6930

1926.502 D17

Other-than-serious 1 instance 1 exposed
Issued
Aug 29, 2012
Penalty
Initial $2,970 · Current $2,970
29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head.    On or about 8/2/2012, at the Emory Eastside hospital job site, employees were exposed to bodily injury as they were not donning full body harnesses properly and instead had the D-ring of the harness positioned at the small of the users back.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $2970
  • — Z (S) $2970

1926.503 A01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Aug 29, 2012
Penalty
Initial $4,950 · Current $0 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards.    On or about 8/2/2012, the employer did not train each employee who was exposed to fall hazards of up to 15 feet in the hazards associated with roof work.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4950

View Peach State Roofing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335761581.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.