Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THARP CABINET CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THARP CABINET CORPORATION in 1246 DENVER AVE, LOVELAND, CO 80537 (NAICS 337110). OSHA activity number 335987780.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tharp Cabinet Corporation — free Get an email when a new federal OSHA severe-injury report for Tharp Cabinet Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1246 DENVER AVE
City
LOVELAND
State
CO
ZIP
80537
Mailing
1246 DENVER AVE., LOVELAND, CO 80537
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
73
Ownership type
A

4 citations on file for this inspection.

1910.213 C02

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 12, 2012
Abate by
Sep 19, 2012
Penalty
Initial $1,785 · Current $1,785
29 CFR 1910.213(c)(2):  Handfed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator:    (a)Tharp Cabinet Corporation at 1246 Denver Ave., Loveland, CO 80537:  A Powermatic tablesaw in the Specials area was not equipped with a spreader.  This condition exposed the employees to a kickback hazard.    Abatement Note:  To properly guard the saw:    (a)The spreader shall:    (1)The spreader shall be made of hard tempered steel, or its equivalent, and shall be thinner than the saw kerf.    (2)The spreader shall be of sufficient width to provide adequate stiffness or rigidity to resist any reasonable side thrust or blow tending to bend or throw it out of position.    (3)The spreader shall be attached so that it will remain in true alignment with the saw even when either the saw or table is tilted.
Recent events (1)
  • — Z (S) $1785

1910.213 F02

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 12, 2012
Abate by
Sep 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.213(f)(2):  Handfed circular ripsaw(s) were not furnished with a sectional non-kickback fingers to prevent material being thrown back on the operator:    (a)Tharp Cabinet Corporation at 1246 Denver Ave., Loveland, CO 80537:  A Powermatic tablesaw in the Specials area was not equipped with a non-kickback device.  This condition exposed the employees to a kickback hazard.    Abatement Note:  To properly guard the saw each self-feed circular ripsaw shall be provided with sectional non-kickback fingers for the full width of the feed rolls. They shall be located in front of the saw and so arranged as to be in continual contact with the wood being fed.
Recent events (1)
  • — Z (S) $0

1910.213 H03

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 12, 2012
Abate by
Sep 19, 2012
Penalty
Initial $1,785 · Current $1,785
29 CFR 1910.213(h)(3):  An adjustable stop was not provided to prevent the forward travel of the blade beyond the position necessary to complete the cut in repetitive operations:    (a)Tharp Cabinet Corporation at 1246 Denver Ave., Loveland, CO 80537: The radial arm saws in the assembly and drawer areas known as "slider saws" traveled beyond the length necessary to complete the cut.  This condition exposed the employee to an amputation hazard.    Abatement Note:  A stop device to prevent any portion of the blade from extending past the cutting surface meets the requirements of this standard.
Recent events (1)
  • — Z (S) $1785

1910.147 C04 II B

Other-than-serious 1 instance 1 exposed
Issued
Sep 12, 2012
Abate by
Sep 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)[B]:  The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.      (a)Tharp Cabinet Corporation at 1246 Denver Ave., Loveland, CO 80537:  The employer did not ensure that the   energy control procedures clearly and specifically outlined the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. This condition potentially exposed the employees and outside contractors to an uncontrolled energy source hazard.    Abatement Note:  Appendix A 1910.147 services as a non-mandatory guideline to assist employers and employees in complying with the requirements of this section, as well as to provide other helpful information. Nothing in the appendix adds to or detracts from any of the requirements of this section.
Recent events (1)
  • — Z (O) $0

View Tharp Cabinet Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335987780.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.