SAN DIEGO, CA —
OSHA Inspection: MARINE CORPS COMMUNITY SERVICES SAN DIEGO
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of MARINE CORPS COMMUNITY SERVICES SAN DIEGO in 3800 CHOSIN AVE BLD 10, SAN DIEGO, CA 92140 (NAICS 448190). OSHA activity number 336161583.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARINE CORPS COMMUNITY SERVICES SAN DIEGO
- Site address
- 3800 CHOSIN AVE BLD 10
- City
- SAN DIEGO
- State
- CA
- ZIP
- 92140
- Mailing
- 1600 HENDERSON AVE, BLDG 5W, SAN DIEGO, CA 92140
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 448190
- Employees
- 11
- Ownership type
- D
Citations
3 citations on file for this inspection.
1910.303 B07 I
- Issued
- Oct 4, 2012
- Abate by
- Oct 24, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: Military Clothing Bld 10, first floor office: On or about 04SEP12, at 1259hrs, 115VAC live conductors were exposed to employee contact where a cover was left off an opening at the corner.
Recent events (1)
- — Z (S) $0
1910.305 G01 III
- Issued
- Oct 4, 2012
- Abate by
- Oct 24, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iii): Flexible cords used as permitted in paragraphs (g)(1)(ii)(C), (g)(1)(ii)(G), or (g)(1)(ii)(I) of 29 CFR 1910.305 were not energized from an approved receptacle outlet: Military Clothing Bld 10, Break Room: On or about 04SEP12, at 1300hrs, a surge suppressor was used to provide 115VAC service to two additional surge suppressors.
Recent events (1)
- — Z (S) $0
1910.305 G02 III
- Issued
- Oct 4, 2012
- Abate by
- Oct 24, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: Military Clothing Bld 10, Break Room: On or about 04SEP12, at 1259hrs, exposed conductors were not provided protection from a pull being directly transmitted to joints or terminal screws where the sheathing of a flexible cord was pulled back from the connection plug.
Recent events (1)
- — Z (S) $0
More inspections at Marine Corps Community Services SAN Diego
View Marine Corps Community Services SAN Diego's full OSHA safety record →
More inspections in this industry (NAICS 448190)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336161583.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.