WARRENSBURG, MO —
OSHA Inspection: STAHL SPECIALTY COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STAHL SPECIALTY COMPANY in 1301 STAHL DRIVE, WARRENSBURG, MO 64093 (NAICS 331521). OSHA activity number 336352380.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STAHL SPECIALTY COMPANY
- Site address
- 1301 STAHL DRIVE
- City
- WARRENSBURG
- State
- MO
- ZIP
- 64093
- Mailing
- 1301 STAHL DRIVE, WARRENSBURG, MO 64093
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331521
- Employees
- 127
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.212 A02
- Issued
- Nov 16, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $4,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(2) Machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points and rotating parts in locations including, but not limited to: a) Employees in the south foundry were exposed to hazard from rotating shafts on cell #2, 3 & 5 blower motors housings. Abatement Note: Abatement certification is not required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $4000
1910.303 B07 IV
- Issued
- Nov 16, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $4,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating (a) The front panel of the Cell 3 tilt machine controller was bent exposing operators to electrical risk as a result of materials entering the damaged cabinet and contacting live parts. Abatement Note: Abatement certification is not required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $4000
1910.303 F02
- Issued
- Nov 16, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $3,000 · Current $500 Reduced
General-duty citation text
29 CFR 1910.303(f)(2) Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident: (a) Employees in the south foundry were exposed to hazard in the event of fire due to circuit breakers which were not identified in an electrical panel. Abatement Note: Abatement certification is not required for this item.
Recent events (2)
- — I (O) $500
- — Z (S) $3000
1910.303 G02 I
- Issued
- Nov 16, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $7,000 · Current $4,400 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): (a) Employees in the north foundry were exposed to risk of electrical shock or electrocution from a flexible cord with exposed live conductors lying on the working platform of cell 16. Abatement Note: Abatement certification is required for this item use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
- — I (S) $4400
- — Z (S) $7000
1910.305 D02
- Issued
- Nov 16, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $5,000 · Current $500 Reduced
General-duty citation text
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures approved for the purpose and were not dead front (a) Electrical panels supplying 3-phase power in the heat treat area did not provide adequate dead front protection as numerous openings were covered with cardboard and/or duct tape. Abatement Note: Abatement certification is required for this item use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
- — I (O) $500
- — Z (S) $5000
More inspections at Stahl Specialty Company
View Stahl Specialty Company's full OSHA safety record →
More inspections in this industry (NAICS 331521)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336352380.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.