Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LAND O' LAKES PURINA FEED LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of LAND O' LAKES PURINA FEED LLC in 505 PALMER ST., WOOSTER, OH 44691 (NAICS 424510). OSHA activity number 336471990.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Land O' Lakes Purina Feed LLC — free Get an email when a new federal OSHA severe-injury report for Land O' Lakes Purina Feed LLC is published. One employer, no account, unsubscribe in one click.
Site address
505 PALMER ST.
City
WOOSTER
State
OH
ZIP
44691
Mailing
505 PALMER ST., WOOSTER, OH 44691
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
4
Ownership type
A

8 citations on file for this inspection.

1910.22 A02

Deleted Serious Gravity 1 1 instance 5 exposed
Issued
Feb 4, 2013
Abate by
Feb 22, 2013
Penalty
Initial $2,805 · Current $0 Reduced
29 CFR 1910.22(a)(2):  Floors of workrooms were not maintained in a clean and, so far as possible, a dry condition:    There was a spill of grain dust below and adjacent to the dust collector.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2805

1910.24 H

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 4, 2013
Abate by
Feb 22, 2013
Penalty
Initial $4,675 · Current $2,338 Reduced
29 CFR 1910.24(h):  Standard railings were not provided on the open sides of all fixed industrial stairways and stair platforms:    The handrail on the exterior dryer stairway had no mid-rail.
Recent events (2)
  • — I (S) $2337.5
  • — Z (S) $4675

1910.36 D01

Other-than-serious 2 instances 5 exposed
Issued
Feb 4, 2013
Abate by
Feb 22, 2013
Penalty
Initial $3,740 · Current $0 Reduced
29 CFR 1910.36(d)(1):  Exit route door(s) required keys, tools or special knowledge to open from the inside:    Standard door latch or other approved exit hardware must be used on exit doors:     a)  Exit door in the basement under bin 13 was held closed with a chain and catch.    b)  Exit door located under in the basement under bin 8 was latched with a wood bar and a chain.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3740

1910.37 B04

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Feb 4, 2013
Abate by
Feb 22, 2013
Penalty
Initial $3,740 · Current $0 Reduced
29 CFR 1910.37(b)(4):  Signs were not posted along the exit access indicating the direction of travel to the nearest exit where the direction of travel to the exit was not immediately apparent:    In the center section of the grain bin basement no exit signs were posted to direct employees exiting the building in case of an emergency.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3740

1910.219 C04 I

Serious Gravity 1 1 instance 5 exposed
Issued
Feb 4, 2013
Abate by
Feb 22, 2013
Penalty
Initial $2,805 · Current $1,403 Reduced
29 CFR 1910.219(c)(4)(i):  Unguarded projecting shaft end did not present a smooth edge and end and projected more than one half the diameter of the shaft:    The rotary valve located under the dust collector had a 1 1/4 inch diameter shaft which projected 3 inches; this shaft should not project more than 5/8 inches.
Recent events (2)
  • — I (S) $1402.5
  • — Z (S) $2805

1910.253 B04 III

Deleted Serious Gravity 1 1 instance 5 exposed
Issued
Feb 4, 2013
Abate by
Feb 22, 2013
Penalty
Initial $2,805 · Current $0 Reduced
29 CFR 1910.253(b)(4)(iii):  Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials, a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    Fuel gas and oxygen cylinders were both stored on a cart in the maintenance shop.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2805

1910.305 B01 I

Other-than-serious 1 instance 5 exposed
Issued
Feb 4, 2013
Abate by
Feb 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(i):  Conductors entering boxes, cabinets, or fittings were not protected from abrasions:    Outer jacket of the power cable used to power the grain dryer pulled free of the electric box exposing the inner wires to abrasion against the box edge.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 5 exposed
Issued
Feb 4, 2013
Abate by
Feb 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): The unused openings in cabinets, boxes, and fittings were not  effectively closed:    In the basement of the grain bin building the conveyor control electrical box under bin number 14 had a 3/4 inch hole in the bottom of the enclosure.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Land O' Lakes Purina Feed LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336471990.