WOOSTER, OH —
OSHA Inspection: LAND O' LAKES PURINA FEED LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of LAND O' LAKES PURINA FEED LLC in 505 PALMER ST., WOOSTER, OH 44691 (NAICS 424510). OSHA activity number 336471990.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LAND O' LAKES PURINA FEED LLC
- Site address
- 505 PALMER ST.
- City
- WOOSTER
- State
- OH
- ZIP
- 44691
- Mailing
- 505 PALMER ST., WOOSTER, OH 44691
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424510
- Employees
- 4
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.22 A02
- Issued
- Feb 4, 2013
- Abate by
- Feb 22, 2013
- Penalty
- Initial $2,805 · Current $0 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): Floors of workrooms were not maintained in a clean and, so far as possible, a dry condition: There was a spill of grain dust below and adjacent to the dust collector.
Recent events (2)
- — I (S) $0
- — Z (S) $2805
1910.24 H
- Issued
- Feb 4, 2013
- Abate by
- Feb 22, 2013
- Penalty
- Initial $4,675 · Current $2,338 Reduced
General-duty citation text
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all fixed industrial stairways and stair platforms: The handrail on the exterior dryer stairway had no mid-rail.
Recent events (2)
- — I (S) $2337.5
- — Z (S) $4675
1910.36 D01
- Issued
- Feb 4, 2013
- Abate by
- Feb 22, 2013
- Penalty
- Initial $3,740 · Current $0 Reduced
General-duty citation text
29 CFR 1910.36(d)(1): Exit route door(s) required keys, tools or special knowledge to open from the inside: Standard door latch or other approved exit hardware must be used on exit doors: a) Exit door in the basement under bin 13 was held closed with a chain and catch. b) Exit door located under in the basement under bin 8 was latched with a wood bar and a chain.
Recent events (2)
- — I (O) $0
- — Z (S) $3740
1910.37 B04
- Issued
- Feb 4, 2013
- Abate by
- Feb 22, 2013
- Penalty
- Initial $3,740 · Current $0 Reduced
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit where the direction of travel to the exit was not immediately apparent: In the center section of the grain bin basement no exit signs were posted to direct employees exiting the building in case of an emergency.
Recent events (2)
- — I (S) $0
- — Z (S) $3740
1910.219 C04 I
- Issued
- Feb 4, 2013
- Abate by
- Feb 22, 2013
- Penalty
- Initial $2,805 · Current $1,403 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end did not present a smooth edge and end and projected more than one half the diameter of the shaft: The rotary valve located under the dust collector had a 1 1/4 inch diameter shaft which projected 3 inches; this shaft should not project more than 5/8 inches.
Recent events (2)
- — I (S) $1402.5
- — Z (S) $2805
1910.253 B04 III
- Issued
- Feb 4, 2013
- Abate by
- Feb 22, 2013
- Penalty
- Initial $2,805 · Current $0 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials, a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: Fuel gas and oxygen cylinders were both stored on a cart in the maintenance shop.
Recent events (2)
- — I (S) $0
- — Z (S) $2805
1910.305 B01 I
- Issued
- Feb 4, 2013
- Abate by
- Feb 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering boxes, cabinets, or fittings were not protected from abrasions: Outer jacket of the power cable used to power the grain dryer pulled free of the electric box exposing the inner wires to abrasion against the box edge.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 II
- Issued
- Feb 4, 2013
- Abate by
- Feb 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): The unused openings in cabinets, boxes, and fittings were not effectively closed: In the basement of the grain bin building the conveyor control electrical box under bin number 14 had a 3/4 inch hole in the bottom of the enclosure.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Land O' Lakes Purina Feed LLC
View Land O' Lakes Purina Feed LLC's full OSHA safety record →
More inspections in this industry (NAICS 424510)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336471990.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.