LEBANON, PA —
OSHA Inspection: ARTHUR FUNK & SONS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARTHUR FUNK & SONS, INC. in LEBANON VALLEY FAMILY YMCA 201 N. 7TH STREET, LEBANON, PA 17046 (NAICS 236220). OSHA activity number 336488622.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARTHUR FUNK & SONS, INC.
- Site address
- LEBANON VALLEY FAMILY YMCA 201 N. 7TH STREET
- City
- LEBANON
- State
- PA
- ZIP
- 17046
- Mailing
- 1405 BIRCH ROAD, LEBANON, PA 17042
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.502 B02
- Issued
- Nov 16, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $2,975 · Current $2,080 Reduced
General-duty citation text
29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high: (a) Second Floor of Gym Area Renovation - Employees worked on the second floor, staging equipment in preparation for cutting holes in some concrete block walls to make door way openings. A section of the guardrail system, 17 feet long, along the eastern edge of the second floor had a top rail but no mid rail, exposing employees to a fall hazard, on or about September 21, 2012.
Recent events (2)
- — I (S) $2080
- — Z (S) $2975
1926.502 I02
- Issued
- Nov 16, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $1,785 · Current $1,250 Reduced
General-duty citation text
29 CFR 1926.502(i)(2): All other covers were not capable of supporting, without failure, at least twice the weight of employees, equipment, and materials that may be imposed on the cover at any one time: (a) First Floor of Gym Area Renovation, Bottom of New South Stairway - The employer made a hole in the floor for work to occur on underground electrical. The hole had an opening size of 6 feet 6 inches by 5 feet 5 inches and a depth of 48 inches. The hole had a cover consisting of a single sheet of plywood, partially supported by electrical conduit. The electrical conduit did not have sufficient capacity to take the weight of a falling employee, and the piece of plywood did not completely cover the hole opening, on or about September 21, 2012.
Recent events (2)
- — I (S) $1250
- — Z (S) $1785
1926.502 I04
- Issued
- Nov 16, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard: (a) First Floor of Gym Area Renovation, Bottom of New South Stairway - The employer made a hole in the floor for work to occur on underground electrical. The hole had an opening size of 6 feet 6 inches by 5 feet 5 inches and a depth of 48 inches. The hole had a cover consisting of a single sheet of plywood. This piece of plywood did not have a color coding or marking with the word "HOLE" or "COVER" to provide warning of the hazard, on or about September 21, 2012.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.602 C01 VI
- Issued
- Nov 16, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $2,975 · Current $2,070 Reduced
General-duty citation text
29 CFR 1926.602(c)(1)(vi): Industrial trucks in use did not meet the applicable requirements of design, construction, stability, inspection, testing, maintenance, and operation, as defined in American National Standards Institute B56.1-1969, Safety Standards for Powered Industrial Trucks; powered industrial trucks with defects or in any way unsafe had not been withdrawn from service until restored to safe operating conditions: (a) Front of Gym Area Renovation - The outer covering of a hydraulic hose for raising and lowering the boom of the JCB Loadall 508-40/568108 telehandler, had deteriorated in spots, and this powered industrial truck did not get withdrawn from service for repairs, on or about September 21, 2012.
Recent events (2)
- — I (S) $2070
- — Z (S) $2975
More inspections at Arthur Funk & Sons, INC.
View Arthur Funk & Sons, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336488622.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.