HERMITAGE, PA —
OSHA Inspection: PITT OHIO EXPRESS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PITT OHIO EXPRESS, INC. in 400 LLODIO ROAD, HERMITAGE, PA 16148 (NAICS 484121). OSHA activity number 336564786.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PITT OHIO EXPRESS, INC.
- Site address
- 400 LLODIO ROAD
- City
- HERMITAGE
- State
- PA
- ZIP
- 16148
- Mailing
- 15 27TH STREET, PITTSBURGH, PA 15222
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484121
- Employees
- 134
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.23 C01
- Issued
- Mar 25, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $3,600 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing, or the equivalent, on all open sides: a) terminal, west side, loft area where generator is located. On or about September 25, 2012, the open sides of the loft, 9 feet above the lower level, were not guarded with a standard railing.
Recent events (2)
- — I (S) $2000
- — Z (S) $3600
1910.120 Q06 II
- Issued
- Mar 25, 2013
- Abate by
- May 9, 2013
- Penalty
- Initial $3,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.120(q)(6)(ii): First responders at the operational level did not receive at least eight hours of training or did not have sufficient experience to objectively demonstrate competency in the areas required by 29 CFR 1910.120(q)(6)(ii)(A) through (q)(6)(ii)(F), nor did the employer certify that employees had received required training: a) terminal dock, on or about September 25, 2012, and times prior thereto, employees who contain and control spills and/or leaks from damaged containers holding various hazardous materials including, but not limited to, DiAcid 1550, Icynenes Base Seal and Gold Seal, were not trained in areas/topics covered by 29 CFR 1910.120(q)(6)(ii)(A) through (q)(6)(ii)(F).
Recent events (2)
- — I (S) $0
- — Z (S) $3600
1910.178 A04
- Issued
- Mar 25, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $4,500 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation were performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals were not changed accordingly: a) terminal dock, on or about September 25, 2012, fork extensions, which affect capacity and safe operation of the forklifts, were added without approval from the forklift manufacturer. b) terminal dock, on or about September 25, 2012, the plates and/or decals on the forklifts were not changed after the fork extensions were added to the forklifts.
Recent events (2)
- — I (O) $2000
- — Z (S) $4500
1910.178 L03 I G
- Issued
- Mar 25, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(3)(i)(G): Powered industrial truck operators did not receive initial training in the topic of fork and attachment adaptation, operation, and use limitations: a) terminal dock, on or about September 25, 2012, forklift operators did not receive training on the fork extensions and how they may affect capacity and the safe operation of the forklifts.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.334 A02 II
- Issued
- Mar 25, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $2,700 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): When there was a defect or evidence of damage that might expose an employee to injury, the defective or damaged item was not removed from service, and employees were permitted to use it before repairs and tests necessary to render the equipment safe had been made: a) terminal dock, on or about September 25, 2012, the flexible cord of the skilz saw had been cut and the inner wires were exposed. b) west end of terminal dock, on or about September 25, 2012, the receptacle was damaged and was no longer secured to the wall, the conduit had been pulled from the box and the inner wires were exposed.
Recent events (2)
- — I (O) $2000
- — Z (S) $2700
More inspections at Pitt Ohio Express, INC.
View Pitt Ohio Express, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 484121)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336564786.