Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NAYLOR PIPE COMPANY

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of NAYLOR PIPE COMPANY in 1230 EAST 92ND STREET, CHICAGO, IL 60619 (NAICS 332996). OSHA activity number 336565981.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Naylor Pipe Company — free Get an email when a new federal OSHA severe-injury report for Naylor Pipe Company is published. One employer, no account, unsubscribe in one click.
Establishment
NAYLOR PIPE COMPANY
Site address
1230 EAST 92ND STREET
City
CHICAGO
State
IL
ZIP
60619
Mailing
1230 EAST 92ND STREET, CHICAGO, IL 60619
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332996
Employees
70
Ownership type
A

4 citations on file for this inspection.

1910.252 A02 II

Deleted Serious Gravity 1 2 instances 2 exposed
Issued
Oct 30, 2012
Abate by
Nov 21, 2012
Penalty
Initial $1,785 · Current $0 Reduced

Hazardous substances 0240X100

29 CFR 1910.252(a)(2)(ii):     Fire extinguishers. Suitable fire extinguishing equipment shall be maintained in a state of readiness for instant use. Such equipment may consist of pails of water, buckets of sand, hose or portable extinguishers depending upon the nature and quantity of the combustible material exposed.    a. Fabrication Department/Welding Cells - On or about October 1, 2010, employees were required to perform welding operations and fire extinguishing equipment was not maintained in a state or readiness for instant use. The welding Cells location that were missing suitable fire extinguishing equipment were the following;    1. The welding cell unit on the east wall did not have fire extinguisher for instant use.    2. The welding cell unit on the southeast wall did not have fire extinguisher for instant use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1785

1910.252 C01 II

Other-than-serious 7 instances 11 exposed
Issued
Oct 30, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 073115201620

29 CFR 1910.252(c)(1)(ii):     Screens. When welding must be performed in a space entirely screened on all sides, the screens shall be so arranged that no serious restriction of ventilation exists. It is desirable to have the screens so mounted that they are about 2 feet (0.61 m) above the floor unless the work is performed at so low a level that the screen must be extended nearer to the floor to protect nearby workers from the glare of welding.    a. Fabrication Department - On or about October 1, 2012, employees were required to walk through an area where welders were not entirely screened on all sides and the conditions of the screens were the following;    1. Some portable welding screens had rips, holes, and tears on their clothing material.    2. Several portable welding screens were missing their tie straps on all tubular sides.    3. Two portable welding screens were missing part of their floor base's tubular frame.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.37 B05

Deleted Other-than-serious 1 instance 5 exposed
Issued
Oct 30, 2012
Abate by
Dec 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5):     Each doorway or passage along an exit access that could be mistaken for an exit must be marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g., closet).    a. Fabrication Department/Corner of East wall - On or about October 3, 2012, the doorway between welding cells leading to the Flanges room was not marked with a sign reading " Not an Exit".
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 G02

Deleted Other-than-serious 5 instances 5 exposed
Issued
Oct 30, 2012
Abate by
Dec 13, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 0240X100

29 CFR 1910.157(g)(2):     The employer shall provide the education required in paragraph (g)(1) of this section upon initial employment and at least annually thereafter.    a. Fabrication Department - On or about October 3, 2012, employees were required to conduct welding operations and to use fire extinguishers were not provided with an educational program at least annually. Employees were potentially exposed to the hazards of smoke inhalation and fire.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Naylor Pipe Company's full OSHA safety record →